After connecting battery to main-board, D15-2 should have the voltage of 12.0V to drive CCD sensor. If there is no
the voltage, CCD circuit cannot work.
After connecting battery to main-board, U28_3 should have the voltage of 5V to supply the peripheric
circuits on CCD sensor main-board. If there is no the voltage, CCD signals cannot be converted normally.
CCD Camera Box
U28_3
5V