LAUNCH
X-631 Wheel Aligner Product Service Manual Hardware
2-13
Connecting Sockets
1
Charging power supply socket
6
Middle CCD socket
2
Lithium battery socket
7
LCD socket
3
End infrared emitter diode socket
8
Key-press film socket
4
Middle infrared emitter diode socket
9
LCD backlight lamp socket
5
End CCD socket
10
Clinometer socket
Frequency Setting
10 different frequencies can be set from 429MHz to 438MHz inside the probe rods of X-631wheel aligner.
The frequency interval is 1MHz. The default frequency is set to 433MHz when the equipment leaves factory.
In the special case (when the frequency used is interfered in its frequency band), the current frequency
setting can be changed to other frequency band (please do not hesitate to contact the factory if necessary).
1
2
5
3
4
6
7
8
9
10