LAUNCH
X-631 Wheel Aligner Product Service Manual Maintenance guide
4-3
Key-press is faulty
Related Factors
a)
Key-press locked;
b)
Broken connecting cable.
Check Sequence
Observe and touch the key-press
――
Test the connecting cable
No Inclination Angle
Related Factors
a)
Sensor damaged;
b)
Main-board of probe rod damaged.
Check Sequence
Sensor
――
Main-board of probe rod
Communication Fault
Communication Fault
Related Factors
a)
Different working frequency between the probe rod and the main emitter/receiver box;
b)
The related RF module does not work.
Check Sequence
Check if RF module is working or not (red indicator is flashing when emitting data, and green one is flashing when receiving
data)
――
Check if they are working with the same frequency or not (if working with the same frequency, the red indicator
for RF module is flashing when pressing one of [Up
↑
Down
↓
] buttons on the probe rod, and the green indicators for RF
module on other probe rods are flashing).
Communication Interference
Related Factors
a)
There are electrical devices working with the same frequency around the working site;
b)
The distance is too far (more than 15m) from RF emitter/receiver box to the probe rods.
Check Sequence
Short the distance between the main unit and the probe rods
――
Check if there are interference sources
Software
Faulty Communication
Related Factors
a)
Error in “Check.ini” file ( incorrect probe rod address, incorrect PC address and incorrect serial port setting;
b)
Check if the serial port works normal under the hardware configuration of PC set.