X-631 Wheel Aligner Product Service Manual Appendix 6
10-6
Install four probe rods on the calibration frame in turn
6.
Adjust four probe rods level according to the indications of the mechanical level bubbles, and lock the probe rods
well and then switch on them;
7.
Enter X-631+ Calibration Program to perform the calibration operation. Click [NEXT] button in turn without paying
attention to the prompts on each interface (about 10 interfaces in total), but when the system performs data
acquisition operation, please wait for 3 seconds at least before you clicking [NEXT] button.