LAUNCH
X-631 Wheel Aligner Product Service Manual Appendix 4
8-7
1
Main processor and interface circuit
2
Power supply and charging circuit
3
End-part (with long connecting cable) CCD signal processing circuit
4
Middle-part (with short connecting cable) CCD signal processing circuit
5
RF module related circuit
6
Clinometer related circuit
Replace the main-board according to the above figure. Connect each connecting terminal. Special attention: Do not confuse
the end-part and middle-part CCD connecting cables. After the connecting cables are connected well, please perform the
following operations:
Run: installation directory \ ProbeUpdate.exe, the interface is as shown in the following:
1
2
3
4
5
6
6