X-631 Wheel Aligner Product Service Manual Appendix 3
7-2
Main Unit RF Module
B. The Instructions for the Frequency Adjustment of the Probe Rod RF Modules
The following Instructions are about the Frequency Adjustment of the Probe Rod RF Modules. Please refer to the following
Figure:
1.
Entering RF setting mode. Press Backlight key and Run-out Compasation key at the same time, and then switch on
the probe rod to enter RF setting mode. Now LCD screen will display the menu of the radio frequency;
2.
Selecting desired radio frequency. Select desired radio frequency by using Previous key and/or Next key. The
frequency pointed by arrow head is of the current frequency which you have selected.
3.
Setting RF communication frequency. Press Previous key and Next key at the same time, set the current frequency as
the RF communication frequency. The screen will display “Set Succeed” after the setting operation is successful.
4.
Press POWER key to switch off, and then switch on. The system starts to perform communication with the new radio
frequency.
The following figure shows the key-press of the probe rod:
Backlight Previous Next Run-out Compasation Power