background image

8

9

UK

 ManSafe

®

 SRL  

 User 

Instructions

The user must read, understand and follow this instruction 
manual before using this equipment. This manual must be kept 
in a safe place for future reference and inspection/recertification 
records and should be used as part of an employee training 
program. It is essential for the safety of the user that if the SRL is 
resold outside the original country of destination the reseller shall 
provide instructions for use, maintenance, periodic examination 
and for repair in the language of the country in which the device 
will be used. 

Latchways SRL shall only be used by a person who is trained and competent 
in its safe use. Contact Latchways if you have any concerns regarding the 
use, maintenance, applications or operation of this device.

Fitness and age significantly affect a person’s ability to safely withstand 
fall  arrest  loads.  Only  people  who  are physically and mentally fit and 
healthy, not under the influence of drugs or alcohol are permitted to use 
this equipment. If you are uncertain about your ability, consult your doctor. 
Latchways SRLs must not be used by pregnant women or minors.

Intended purpose: 

The Self Retractable Lifeline (SRL) in accordance 

with EN360:2002 is intended to be used as a connecting element within 
a personal fall arrest system. It must be used vertically in situations where 
user mobility is required and fall protection is needed - inspection, general 
construction and maintenance work etc. 

Product Limitations:

 Latchways SRL shall not be used outside its 

limitations, or any purpose other than that for which it is intended. All 
maintenance work is to be conducted by an authorised person. Do not 
attempt to modify or repair the equipment. Failure to follow these instructions 
or misuse of this equipment may result in serious injury or death.

1  The SRL is for a single user only, only one person can be connected at 

any time 

A

2  Maximum user weight (including tools) is 140 kg 

B

3  SRL must be protected from fire, acids, caustic solutions, welding 

flames, sparks or similar. 

4  Latchways SRLs can be used in temperatures ranging from 

 

-30°C to +50°C. 

5  This device should be positioned as vertically as possible above the 

position of the user and used at an angle that is no more than 30° to 
the vertical 

C

6  The SRL must not be used if there is any risk of the SRL contacting high 

voltage power lines.

7  Latchways recommends that the SRL should not be used in conjunction 

with a caged ladder. 
HSE research has previously found that caged ladders (i.e. ladders 
with hoops) could not provide positive fall arrest capability. Further 
research has shown that there is a risk of the user striking the cage in 
the event of a fall or the caged ladder interfering with the performance 
of a Fall Arrest System. In addition to this, rescue of a casualty could 
be hindered by the caged ladder.

8  Mansafe Sealed SRL’s are suitable for use in areas in which explosive 

atmospheres caused by mixtures of air and gases, vapours or mists or 
by air/dusts mixtures are likely to occur, as per BS EN 13463-1:2001 
equipment group II, category 2 (

II 2 G c IIC T6).

9  As a safety precaution in some industries, it is required that any object 

connected at height is tethered to the structure with an additional ‘back 

up’ connection. The Sealed SRL has been designed to incorporate a 
unique carry handle, which has also been tested for use as the 
secondary retention point.

Secondary 

retention point

Main anchor 

connection

WARNING! The secondary retention point can only be used as a 
method of tethering the Sealed SRL back to the structure and 
must NEVER be used as the main anchor connection.

System requirements: 

A fall arrest system comprises of a structural 

anchor point, full body harness, connector (karabiner/hook) and SRL. 
Ensure all elements in the system are used only as specified by the 
manufacturer. It is essential for safety that the anchor device and anchor 
point should always be positioned, and work carried out in such a way, as 
to minimise both the potential for a fall and potential fall distance. 

WARNING! Incompatible components can lead to connectors 
accidentally disengaging. Always ensure all connectors are 
correctly engaged and locked.

1  Connectors must conform to EN 362 and be self closing and self locking. 
2  A full body harnesses conforming to EN 361 

must be worn when using Latchways SRL. 

3  The anchorage structure must be able to 

sustain a minimum force of 10 kN 

D

Latchways recommends using a certified 
anchor point. Refer to EN 795. If more than 
one personal fall arrest system is attached to 
the same supporting structure then the 
former strength requirement has to be multiplied by the number of 
personalfall arrest systems attached to the supporting structure.

4  A minimum of 3 m from the working level to the nearest obstruction, 

lower level or ground underneath a hazard should be maintained.

5  An emergency rescue plan must be in place, to be implemented in the 

event of a fall. 

NOTE:

 Selection of the anchor point position must take in to account any 

risks posed by moving machinery and pendulum falls. To ensure positive 
locking of the SRL a clear, unobstructed fall path is necessary. Do not use 
the SRL when working on such materials as sand or grain, as this may not 
allow sufficient speed to cause the SRL to lock in the event of a fall. It is 
essential for safety to verify the free space required beneath the user at the 
workplace before each occasion of use, so that, in the event of a fall there 
will be no collision with the ground or other obstacle in the fall path. 

Operation and use:

 Attach the SRL overhead to a suitable anchorage 

or anchorage connector. Perform a pre-use check of the equipment, to 
ensure that it operates correctly. To check operation pull smoothly on the 
lifeline listening for the audible clicking, then pull sharply on the lifeline to 
engage the locking mechanism. 

Connect the self locking snap hook 
on the end of the lifeline to the 
designated fall arrest attachment 
point of a full body harness 

E

Once connected to the SRL the 
user  is  free  to  move  about  the 
working area. The lifeline will extract and retract without hesitation. If the 
lifeline is prevented from retracting during normal use, extract the lifeline 
fully and allow it to retract under tension. Then check the locking function 

of the device. If the lifeline continues to not retract fully then return the 
SRL to an authorised person for inspection and recertification. An increase 
in fall distance can occur if the lifeline is prevented from retracting, this 
must be avoided. 

1  Never attach an additional lanyard or similar component to lengthen 

the line. 

2  Do not allow the lifeline to pass through legs or under arms.
3  This product is intended for overhead applications only. Never use this 

product for ground level attachments or cable systems 

F

.  Never  use 

over an edge 

G

4  Do not allow the lifeline to be in contact with or rub against sharp edges.

NOTE:

 When the SRL is not in use, do not allow the lifeline to be fully 

extracted for long periods of time as this may cause weakening of the 
retraction spring. Do not let go of the lifeline as it will retract at high speed 
potentially damaging internal parts. If the SRL is positioned high above 
the users head, the use of a tag line/second line is acceptable to allow 
the SRL to fully retract. Tag lines/second lines must be removed from the 
device before use. 

Inspection instructions:

 Regular and periodic examinations of the SRL 

are required to ensure the safety of the user, which is dependent on the 
continued efficiency and durability of the SRL.  

1  Inspect the SRL to see if the 

visual load indicator has 
deployed, this will determine if 
a fall has occurred. Latchways 
Sealed SRL incorporate an 
indicating swivel hook designed 
to deploy in the event of a fall. If 
any red colour is visible around 
the swivel area of the hook then loading has occurred 

H

2  Inspect to ensure all labels are present and fully legible.
3  Inspect connecting hooks or karabiners for working condition and 

signs of damage or corrosion.

4  Visually inspect the entire unit for signs of 

corrosion, damage or distortion. Ensure all 
fastenings are present and secure. 

5  Fully extract the lifeline. As the lifeline retracts it 

must do so without hesitation (no slack line 
should occur). During extraction and retraction 
ensure that a clicking sound can be heard 
which indicates that the locking mechanism is 
functioning correctly 

I

.

6  Pull the lifeline sharply making sure that this 

causes the device to lock up.

7  Inspect lifeline. If the lifeline has any cuts, 

broken strands, kinks, bird-caging, welding 
spatter, burns, abraded areas or shows 
signs of excessive soiling, corrosion or UV 
degradation it must be replaced 

J

.

WARNING! If the SRL has been subjected to loading, or you are 
in any doubt concerning the safety or condition of the device, it 
must be removed from service immediately and recertified by an 
authorised person. It may not be used again until confirmed in 
writing by a competent person that it is safe to do so.

A periodic examination of the device should be completed by an authorised 
person other than the user at least every 12 months. Local legislation or 
environmental conditions (corrosive or chemical environments) may dictate 
more frequent recertification intervals. 

NOTE:

 It is mandatory that a full service of this product be completed within  

2 years of manufacture and annually thereafter.

The life of the product can be affected by environmental conditions. 

 

If, during periodic inspection by a competent person, the product is 
deemed unsafe it should be removed from service. 

NOTE:

 Authorised person means a person who is trained and approved 

by Latchways in identifying hazards or dangerous conditions of the self 
retracting lifeline.

It is the responsibility of the site safety officer or the user to maintain a 
record of each periodic inspection in the recertification log which can be 
found at the front of this manual.

Maintenance, Storage and Transportation:

 If required, clean the 

SRL exterior, lifeline and labels (to maintain legibility) with warm water 
(40°C) and non biological detergent then rinse. An excessive build-up of 
dirt or paint etc. on the lifeline may compromise the retraction. If the SRL 
becomes wet, either from being in use or from cleaning, position the SRL 
such that any excess water can drain out and leave to dry naturally away 
from direct heat. The full body harness and any other system components 
should be cleaned and stored according to manufacturer’s instructions.

Store the SRL in a cool, dry, clean environment. Ensure SRL is away from 
dust, oil and direct sunlight. Inspect the SRL after long periods of storage. 

During transportation the device must be protected to prevent damage 
or contamination.

A

G

F

B

C

< 10 KN

“tic, tic”

No part of this document may be reproduced or transmitted in any form or by any means, without prior permission in writing from Latchways plc.

Summary of Contents for ManSafe

Page 1: ...nSafe Sealed SRL User Instructions Mode d emploi Anweisungen f r den Benutzer Gebruikersinstructie Instrucciones de Usuario Istruzioni per l utente Brugervejledning Bruksanvisning Anv ndarinstruktione...

Page 2: ...les exigences et sp cifications de la norme EN 360 2002 Les dispositions concernant le contr le qualit adopt es l gard de ce produit sont conformes aux conditions de la norme ISO 9001 2000 Wir best t...

Page 3: ...de seguridad de obra o el usuario Da completare da parte di persona autorizzata e mantenuto dal responsabile della sicurezza o dall utente Udfyldes af en bemyndiget person og vedligeholdes af den ste...

Page 4: ...ate of Manufacture Date de fabrication Herstellungsdatum Fabricage datum Fecha de Fabricaci n Data di produzione Fabrikationsdato Produksjonsdato Tillverkningsdatum 7 Notified Body Organisme notifi Ge...

Page 5: ...ce required beneath the user at the workplace before each occasion of use so that in the event of a fall there will be no collision with the ground or other obstacle in the fall path Operation and use...

Page 6: ...que du sable ou des grains tant donn que la vitesse ne sera pas suffisante pour d clencher le blocage de la LAR en cas de chute Pour des raisons de s curit il est essentiel de v rifier l espace requi...

Page 7: ...nicht die ausreichende Geschwindigkeit f r die SRL Sperre im Fall eines Absturzes gegeben ist F r die Sicherheit ist es wesentlich den erforderlichen freien Raum unterhalb des Arbeitsplatzes des Benut...

Page 8: ...ng wanneer een eventuele val zou plaatsvinden Gebruik de SRL nooit op plaatsen waar gewerkt wordt met materialen die bestaan uit zand of granen Vervuiling hiervan in het apparaat kan ervoor zorgen dat...

Page 9: ...arena o grano ya que podr an no permitir una velocidad suficiente para provocar el bloqueo de la SRL en caso de ca da Por motivos de seguridad es imprescindible comprobar que existe el espacio libre...

Page 10: ...n consentire una velocit sufficiente a provocare il bloccaggio dell SRL in caso di caduta Per la sicurezza fondamentale verificare lo spazio libero richiesto al di sotto dell utente sul posto di lavor...

Page 11: ...der ikke nedenunder findes nogle hindringer som en person kan ramme ved et fald Brug ikke SRL n r der arbejdes p s danne materialer som sand eller korn da disse evt ikke kan g re det muligt for SRL a...

Page 12: ...t in the event of a fall there will be no collision with the ground or other obstacle in the fall path MERK Ved valg av forankringspunkt m det tas hensyn til risikoer for rsaket av bevegelige maskiner...

Page 13: ...ial eftersom dessa riskerar att inte m jligg ra den hastighet som kr vs f r att SRL en ska l sa sig i h ndelse av ett fall Det r avg rande f r s kerheten att s kerst lla att det fria utrymme som kr vs...

Page 14: ...26 27...

Page 15: ...il info latchways com Website www latchways com ManSafe and Constant Force are registered trademarks and Full Contact is a trademark of Latchways plc All contents of this manual are Copyright Latchway...

Reviews: