11
Liquid ingress protection
The second digit indicates the level of protection that the enclosure provides against
harmful ingress of water.
Level
Protected
against
Testing for
Details
0
Not
protected
—
—
1
Dripping
water
Dripping water (vertically
falling drops) shall have no
harmful effect.
Test duration: 10 minutes
Water equivalent to 1 mm
rainfall per minute
2
Dripping
water when
tilted up to
15°
Vertically dripping water
shall have no harmful effect
when the enclosure is tilted
at an angle up to 15° from
its normal position.
Test duration: 10 minutes
Water equivalent to 3 mm
rainfall per minute
3
Spraying
water
Water falling as a spray at
any angle up to 60° from
the vertical shall have no
harmful effect.
Test duration: 5 minutes
Water volume: 0.7 litres per
minute
Pressure: 80
–100 kPa
4
Splashing
of water
Water splashing against
the enclosure from any
direction shall have no
harmful effect.
Test duration: 5 minutes
Water volume: 10 litres per
minute
Pressure: 80
–100 kPa
5
Water jets
Water projected by a
nozzle (6.3 mm) against
enclosure from any
direction shall have no
harmful effects.
Test duration: at least
15 minutes
Water volume: 12.5 litres per
minute
Pressure: 30 kPa at distance
of 3 m
6
Powerful
Water projected in powerful
Test duration: at least
Summary of Contents for IES-3208C
Page 16: ...9...
Page 31: ...24 Multiple Rings...
Page 32: ...25 Dual Homing Chain...
Page 33: ...26...
Page 58: ...51 C You can set the forwarding method of port break event in here...
Page 77: ...70 Demo Demo display each topology in different connection...
Page 103: ...96 6 15 2 3 Remember to press Apply 6 15 1 4 Save setting...
Page 110: ...103...
Page 115: ...108 The setting of none switch 6 18 Dual Homing...
Page 122: ...115...
Page 141: ...134...