67
as followings:
Nothing: No action
Power Down: shutdown the power of the PoE port
Power On: keep the power on with the PoE port
Restart Forever: Restart the power of the PoE port always.
Restart Once: only restart the PoE power one time.
Reboot time
To set the reboot time of PD in order for the switch to check PD connection after
PD is completely boot up.
6.7.8 Scheduling(Mode B)
The Poe scheduling is to feed or shut down PoE power over a routine schedule in the
following table. Enable the square of time will power on the PD at dedicated time.