Function
Note
Min Defau
lt
Max Factor
Unit
b4
Response of the door drive for
obstruction in Close direction
oF = if door is obstructed, the drive
will stop immediately. If the input
signal changes to "Open door",
open the door.
on = automatic reversing for input
signal "Close door" until the
Opened position is reached. If the
input signal "Close door" is still
present, the door will then close
again immediately.
oF oF on
b5
Activation of Obstructed
detection in Open direction
oF = Off
on = On
oF on on
b6
Suppression of Obstructed
detection in the first 30% of the
Open distance.
oF = Off
on = On
oF On on
b7
Limit value of Obstructed
detection in Open direction
0.1
9.5
9.9
[A]
b8
Response of relay output "Door
Obstructed" in Open direction
oF = Continuous
on = Pulse
oF on on
b9
Response of the door drive for
blocking in Open direction
oF = if door is Obstructed the drive
will stop immediately. If the input
signal changes to "Close door",
close the door.
on = automatic reversing for input
signal "Open door" until the Closed
position is reached. If the input
signal "Open door" is still present,
the door will then open again
immediately.
oF oF on
bA
Length of the output pulse on
relay output "Door Obstructed"
in Open and Close direction
Only in effect if b3 and/or
b8 = on
0.1 1.0 2.0
[seconds]
bb
Catch range for Door Closed
position
Caution:
Obstructed detection is
not active in this range!
01 10 50
[mm]
bC Catch range for Door Opened
position
Caution:
Obstructed detection is
not active in this range!
01 10 50
[mm]
bE
Slow travel when door blocked. If the door is blocked in the close
direction, the TSG will drive slowly
on the next closing run until it
reaches the position of the
blockage.
oF on on