![Langer & Laumann TSG 400 Operating Instructions Manual Download Page 23](http://html.mh-extra.com/html/langer-and-laumann/tsg-400/tsg-400_operating-instructions-manual_674760023.webp)
23
Langer & Laumann Ingenieurbüro GmbH 48356 Nordwalde Wallgraben 30
+49 (02573) 9 55 99 0
http://www.LuL-Ing.de
+49 (02573) 9 55 99 5 Email: [email protected]
Langer & Laumann
I n g e n i e u r b ü r o G m b H
Geschäftsführer
Dipl.- Ing. Michael Laumann
Dipl.- Ing. Matthias Langer
/ Managing Director
Bankverbindung
Sparkasse Steinfurt
/ Bank Account
BLZ: 40351220 Kto: 7024631
WELADED1STF
De52 4035 1060 0007 0246 31
BLZ: 40061238 Kto: 8623333000
GEBODEM1GRV
De66 4006 1238 8623 3330 00
BIC
IBAN
Volksbank Greven EG
BIC
IBAN
Handelsregister
Amtsgericht Steinfurt HRB 2943
Ust.-Id.Nr.
De195553428
Steuer-Nr. 311 5870 1056
/ Comercial Register
/ Vat-No.
Function
Note
Min Defau
lt
Max Factor
Unit
h3 Function of Input X1.3
00: No Function
01: Light Curtain "normally open"
If LED 12 is lit open the door
02: Light Curtain "normally
closed"
If LED 12 is not lit open the door
03: Light Curtain "normally
closed" plus the next closing run
at a slower speed
If LED 12 is not lit open the door
at slow speed for the next run.
00 00 03
h4 Switching delay of "door is open"
output relay
With this parameter a delay
(distance) of switching of the
"door is open" output relay can
be set.
Caution:
If change h4 larger than
00, an additional distance of
5[cm] will be added.
00 00 10 0.01 [m]
h6 Speed during calibration and
after power is restored
Speed when searching for end
position following power failure
and during the learning
procedure (see also P9).
01 09 25 0.01 [m/s]
h7 Speed after power has been
restored for the second operation
(trip).
Search speed for the end position
following voltage recovery after
the first item has been found.
If h7 is set to 00, only the first
item for referencing is required.
The second trip will be driven at
normal speed.
00 00 25 0.01 [m/s]
h8 Force for verifying the end
position in CLOSED
0.1
3.5
9.9
[A]
h9 Force for verifying the end
position in OPEN
0.1
1.0
9.9
[A]
hA Activation
add on board
Only for use with optional add on
boards (valid from version 4.25.1)
00: message operational
01: skate drive (e.g. QKS9)
02: retiring cam magnet (e.g.
KONE ADC)
03: interlock (e.g. Koch)
00 00 03