24
Langer & Laumann Ingenieurbüro GmbH 48356 Nordwalde Wallgraben 30
+49 (02573) 9 55 99 0
http://www.LuL-Ing.de
+49 (02573) 9 55 99 5 Email: [email protected]
Langer & Laumann
I n g e n i e u r b ü r o G m b H
Geschäftsführer
Dipl.- Ing. Michael Laumann
Dipl.- Ing. Matthias Langer
/ Managing Director
Bankverbindung
Sparkasse Steinfurt
/ Bank Account
BLZ: 40351220 Kto: 7024631
WELADED1STF
De52 4035 1060 0007 0246 31
BLZ: 40061238 Kto: 8623333000
GEBODEM1GRV
De66 4006 1238 8623 3330 00
BIC
IBAN
Volksbank Greven EG
BIC
IBAN
Handelsregister
Amtsgericht Steinfurt HRB 2943
Ust.-Id.Nr.
De195553428
Steuer-Nr. 311 5870 1056
/ Comercial Register
/ Vat-No.
Function
Note
Min Defau
lt
Max Factor
Unit
hb Closing and opening time of the
skate
Only with additional board that
can be optionally fitted and
hA=01 or hA=03
0.1 0.7 3.0
[seconds]
hC Pause between opening of the
skate and opening of the door
Only with additional board that
can be optionally fitted and
hA=01 or hA=03
0.1 0.7 3.0
[seconds]
hd Torque to find the end position in
Close direction while teaching
0.1
5.0
9.9
[A]
hE Torque to find the end position in
Open direction while teaching
and reference
0.1
5.0
9.9
[A]
hF Suppression of Blockage
detection in the last 0mm to
50mm(maximum) in the close
direction.
The maximum setting of 50mm is
a combination of parameters bb +
hF
for example: if bb = 10mm then
hF -> = 40mm (Max)
Warning:
in this distance the
blockage detection is disabled.
00 00 50
[mm]
CC Exit the menu.
Select CC and press the jog wheel to leave the h-parameter menu and
return to c.o.