(06) Preset Register
Query
Response
Slave Address
11
Slave Address
11
Function
06
Function
06
Register Address Hi
00
Register Address Hi
06
Register Address Lo
20
Register Address Lo
xx
Data Hi
00
Data Lo
xx
Data Lo
03
Data Hi
xx
CRC Hi
xx
CRC Hi
xx
CRC Lo
xx
CRC Lo
xx
(10 Hex) Preset Multiple Registers
Query
Response
Slave Address
11
Slave Address
11
Function
10
Function
10
Register Address Hi
00
Register Address Hi
00
Register Address Lo
01
Register Address Lo
01
No. of Registers Hi
00
No. of Registers Hi
00
No. of Registers Lo
02
No. of Registers Lo
02
Byte Count
02
CRC Hi
xx
Data Hi
xx
CRC Lo
xx
Data Lo
xx
Data Hi
xx
Data Lo
xx
CRC Hi
xx
CRC Lo
xx
CRC Generation
Consult the MODBUS manual available at www.modbus.org.