![Land 4500 MKII Premier Operation And Maintenance Manual Download Page 126](http://html1.mh-extra.com/html/land/4500-mkii-premier/4500-mkii-premier_operation-and-maintenance-manual_3476555126.webp)
Model 4500 Premier Dust and Opacity Monitor
126
C6-2 Maintenance
The Land Instruments International Model 4500 Premier has been designed for a minimal amount
of routine maintenance . To ensure a maximum monitor lifetime however, the following maintenance
schedule has been developed. Remember that the air purge system should always be left on, even if
the boiler is off, to prevent any contamination of the optics. In exceptionally dirty facilities, the time
periods below should be shortened. Frequent “Op0 limited” alarms or blower faults may indicate a
need to shorten the maintenance period.
ITEM
PART
MAINTENANCE
PROCEDURE
Air Hoses
318.239
90 Days
Examine hoses for holes or leaks.
Test all hose clamps for tightness.
Pre-filter
701.983
90 Days
Dust level should be below the line.
(Where fitted)
Remove, empty, wipe out, and replace.
Filter cover
N/A
90 Days
Remove the filter from the filter housing.
/Rubber cup
Remove the rubber cup. Empty the cup,
(Where fitted)
wipe out, and replace.
Filter Element
317.441
90 Days
Wear eye protection, tap gently to remove
dust. Clean carefully with a blow gun.
Examine for holes or rips. Re-fit.
Annually
Replace with new filter.
Blower
90 Days
Check for bearing noise. (Bearing
failure, and subsequent blower failure,
can be detected early.) Check blower air
flow to be sure that the blower is
performing normally. (Dirty air filters may
reduce air flow and cause undue stress
on the blowers.)
Optics
N/A
90 Days
Check and clean the optics as described
below.
Air Purge
N/A
90 Days
Open the Transmissometer or
Adapter
Retro-Reflector on its hinge and check
that there is no ash buildup inside the
adapter that could block the light path.