Cleaning & Sanitizing Ice Bin, Auger, and
Ice Chute
1. Disconnect power to the dispenser
2. Remove the Merchandiser and Top Cover.
3. Remove Ice Chute Lever, then remove Splash Plate
Assembly by lifting it up and out from the dispenser face.
Refer to the Automatic Agitation Warning on the
second page of this manual.
NOTE
It is recommended to perform this procedure monthly,
or more often if desired. Use the cleaning solution
described on page 19. An alternate solution of one
parts water to one part vinegar may be used to remove
water spots and calcium deposits.
NOTE
Always remove the ice chute lever before removing the
splash plate.
NOTE
4. Remove or melt out any remaining ice from the ice bin.
5. Use a screwdriver to remove the Auger Motor shaft cover.
6. Remove the “C” clip from the Auger Motor Shaft.
A
B
C
A. Auger Motor Shaft
B. “C” Clip
C. Ice Chute
9.
Slide the Motor and Mounting Plate Assembly off of the
Auger Shaft.
7. Disconnect the Auger Motor wire harness from junction box.
8.
Remove the four (4) screws from the bracket holding the
Auger Motor, and LED light bracket.
3. Using the nozzle brush provided in the installation kit and
the cleaning solution described on page 19, clean the outer
nozzle of any residual syrup.
4. Rinse the outer nozzle with clean, potable water then soak in
the nozzle sanitizing solution.
5. While the outer nozzle is in the sanitizing solution, using the
nozzle brush, dip the brush in the nozzle sanitizing solution
and thoroughly brush the bottom of the inner nozzle body.
6. Rinse the brush in warm 90° – 110°F (32.2°– 43.3°C), clean
potable water and brush the bottom of the inner nozzle body
once more
WITHOUT
the sanitizing solution.
7.
After the outer nozzle has soaked for fifteen (15) minutes,
rinse in warm 90° – 110°F (32.2°– 43.3°C), clean potable
water for a minimum of twenty (20) seconds ensuring all
surfaces of the nozzle have been thoroughly rinsed.
8.
Allow outer nozzle to air dry (to expedite drying, forced
convection is recommended).
9. Reinstall the outer nozzle to the unit.
10. Repeat Steps 1 - 9 for the second nozzle.
11. Wipe down push levers with solution.
Cleaning & Sanitizing Nozzles
1. Remove the nozzle cover by squeezing sides and pulling
down.
2. Remove nozzle by twisting counterclockwise and pulling
downward.
DO NOT
attempt to activate any valves while the outer
nozzle is removed.
!
ATTENTION
N’essayez PAS d’activer des vannes lorsque la buse
extérieure est retirée.
!
ATTENTION
Il est recommandé d’effectuer cette procédure une
fois par mois, ou plus souvent si vous le souhaitez.
Utilisez la solution de nettoyage décrit à la page 19.
Une solution alternative d’une part d’eau pour une part
de vinaigre peut être utilisée pour éliminer les taches
d’eau et les dépôts de calcium.
REMARQUE
Consulter la mise en garde relative à l’agitation
automatique à la page 2.
NOTE
Toujours retirer le levier faisant chuter les glaçons avant
de retirer la plaque antiéclaboussures.
NOTE