background image

18

5.  In the “Update from USB” section, tap the 

Brands

 button. 

 

There will be a check mark next to the Brands button if 

the USB drive has the brand files in the correct place.

NOTE

To upload new flavors to the Twin Pour 30, create the 

flavor.brand

 file and put into a folder named “flavors”, 

then repeat steps 2-5. 

NOTE

The operator of the equipment must provide continuous maintenance as required by this manual and/or state and local 

health department guidelines to ensure proper operation and sanitation requirements are maintained.

The cleaning procedures provided herein pertain to the Lancer equipment identified by this manual. If other equipment 

is being cleaned, follow the guidelines established by the manufacturer for that equipment.
Cleaning should be accomplished only by trained personnel. Sanitary gloves are to be used during cleaning operations.           

Applicable safety precautions must be observed. Instruction warnings on the product being used must be followed.

GENERAL INFORMATION

CLEANING AND SANITIZING

 

Il y aura une coche à côté du bouton Marques si la clé 

USB contient les fichiers de marque au bon endroit.

REMARQUE

 

Pour télécharger de nouvelles saveurs sur le Twin Pour 

30, créez le fichier flavour.brand et placez-le dans un 

dossier nommé «saveurs», puis répétez les étapes 2 à 5

REMARQUE

À sa sortie de l’usine, l’équipement Lancer (qu’il soit nouveau ou remis à neuf) a été nettoyé et aseptisé conformément 

aux lignes directrices de la NSF. L’exploitant de l’équipement doit en assurer l’entretien continu comme indiqué dans 

ce manuel ou selon les lignes directrices du ministère de la Santé afin d’assurer qu’il demeure conforme aux exigences 

sanitaires et de fonctionnement.

Les procédures de nettoyage vérifiées dans les pages présentes visaient l’équipement Lancer identifié dans ce manuel. 

Pour nettoyer tout autre équipement, il faut suivre les lignes directrices prévues par le fabricant de cet équipement.

Le nettoyage doit être effectué uniquement par du personnel qualifié. La personne effectuant le nettoyage doit porter 

en tout temps des gants stériles. Toute précaution applicable en matière de sécurité doit être prise. Les avertissements 

intégrés aux instructions indiquées sur le produit doivent être respectés.

Renseignements Généraux

•  Use sanitary gloves when cleaning the unit and observe all applicable safety precautions.

•  DO NOT

 use a water jet to clean or sanitize the unit.

•  DO NOT

 disconnect water lines when cleaning and sanitizing syrup lines, to avoid contamination.

•  DO NOT

 use strong bleaches or detergents; These can discolor and corrode various materials.

•  DO NOT

 use metal scrapers, sharp objects, steel wool, scouring pads, abrasives, or solvents on the dispenser.

•  DO NOT

 use hot water above 140° F (60° C). This can damage the dispenser.

•  DO NOT

 spill sanitizing solution on any circuit boards. Insure all sanitizing solution is removed from the system.

•  DO NOT 

use mechanical devices or other means to accelerate the defrosting process, other than those recom-

mended by the manufacturer.

ATTENTION

Summary of Contents for Twin Pour 30

Page 1: ...not be used by children or infirm persons without supervision This appliance can be used by children aged from 8 years and above and persons with reduced physical sensory or mental capabilities or la...

Page 2: ...hez pas cet appareil dans une prise lectrique multiple partag e par d autres appareils Ne placez pas plusieurs prises d alimentation multiples portables ou alimentations lectriques portables l arri re...

Page 3: ...an air gap a backflow prevention device or another approved method to comply with NSF standards A leaking inlet water check valve will allow carbonated water to flow back through the pump when it is s...

Page 4: ...aining three sides Level unit if necessary For optimum perfor mance place the unit at a 0 tilt The maximum tilt is 5 Leveling the Dispenser NSF listed units must be sealed to the counter NOTE To ensur...

Page 5: ...at se trouve dans le bac gla ons Durant le cycle d agitation automatique et lors de la distribution des gla ons veiller ce que l espace soit suffisant entre le dessus de l amas de gla ons et le bas de...

Page 6: ...nect tubing to all syrup inlets See Plumbing Diagrams on page 26 for reference NOTE 12 Route drain hose from designated open type drain to fitting on Drip Tray and connect hose to fitting if applicabl...

Page 7: ...E 13 Attach fan bracket to fan assembly using screws provided Condensation Fan Installation 14 Install condensation fan on the underside of the unit by 1 pushing fan bracket into slots in the right wa...

Page 8: ...OT TURN ON CO2 SUPPLY AT THIS TIME WARNING 7 Repeat Step 6 for both low pressure CO2 regulators on the regulator manifold routed to the unit and the syrup pumps 5 Connect tubing routed from the tee at...

Page 9: ...the service menu for drink setup must be accessed 10 Access the Service Menu by turning the keyswitch clock wise to the third position 6 Turn on the power to the dispenser by pressing the on off toggl...

Page 10: ...oth of the low pressure regulators on the regulator manifold to 75 psi 0 517 MPa then tighten locknut with wrench 22 Activate each soda module until gas out 23 Plug in the remote carbonator pump deck...

Page 11: ...button on the lower left corner to return to the Valve Configuration Screen 7 Repeat Steps 3 and 5 for any of the other brand or flavor modules 8 Tap the Back button to return to the Service menu 12 T...

Page 12: ...bration button 2 Tap the Calibrate on the Water Valve to be calibrated Calibrating Plain Carbonated Water Modules Fill to 200 ml Graduated Cylinder CALIBRATION MAINTENANCE 4 Set the Timer to the ON po...

Page 13: ...r reference The water flow rate was set to 73 93 ml sec which makes the final syrup flow rate 14 79 ml s The finished drink flow rate dispensed will be 88 72 ml s NOTE A B C D Increase Decrease A Flow...

Page 14: ...ttach outer nozzle by pushing up and twisting clockwise until snug 5 Enter the brand calibration screen from the previous section steps 1 2 6 Set the Timer to the ON position and select Time as the Op...

Page 15: ...The following is a set of instructions on how to set up this feature If no sold out sensor is assigned then the Auto feature acts the same as the Ready feature NOTE Sold Out Features 1 From the Servic...

Page 16: ...d scroll down and press Accept to confirm and save changes It may take up to 10 minutes for a network connection to be established NOTE 2 From the service menu select Network Status to change connecti...

Page 17: ...into open port on the side of the PCB controller box 4 Access the Service menu on the left side screen and tap the Data Management button Update Brands Flavors 1 Create a USB drive with the updated b...

Page 18: ...ment aux lignes directrices de la NSF L exploitant de l quipement doit en assurer l entretien continu comme indiqu dans ce manuel ou selon les lignes directrices du minist re de la Sant afin d assure...

Page 19: ...n Box on page 21 Pull out unit if applicable and clean behind and underneath Check for any loose components or noises Other Supplies Needed 1 Clean cloth towels 2 Bucket 3 Extra nozzle 4 Sanitary glov...

Page 20: ...in the sanitizing solution using the nozzle brush dip the brush in the nozzle sanitizing solution and thoroughly brush the bottom of the inner nozzle body 6 Rinse the brush in warm 90 110 F 32 2 43 3...

Page 21: ...all sides of the Ice Bin and surface of the aluminum casting 5 Place syrup lines with BIB connectors and any adapters into cleaning solution 6 Activate each valve until lines are filled with cleaning...

Page 22: ...coming CO2 pressure is between 70 psi 0 483 MPa and 80 psi 0 552 MPa 2 Open shutoff fully 3 Remove soda flow control from valve and clean out any foreign material to ensure smooth spool movement Insuf...

Page 23: ...to syrup pump too low 5 Stalled or inoperative BIB pump 6 Kinked line 7 CO2 regulator malfunction 1 Replace syrup BIB as required 2 Open shutoff completely 3 Remove valve from mounting block open shu...

Page 24: ...Wiring harness not plugged in 3 PC board defective 4 Malfunctioning power supply 1 Connect dispenser to power source 2 Plug in wiring harness 3 Replace PC board 4 Check voltage to power supply Check f...

Page 25: ...ck BIB connector if still leaking then re place line 2 Replace o ring 3 Replace defective pump BIB pump fails to restart after bag replacement 1 BIB connector not on tightly 2 BIB connector is stopped...

Page 26: ...12 14 16 2 4 6 16 8 10 12 14 1 3 5 7 9 NC 11 13 15 NC 1 3 5 15 7 9 11 13 BLK WHT GRY BLK PUR BLU GRN YEL ORG RED BRN VIO BLK BLK GRN BLK BRN BLK ORG BLK BLK BLK GRY PUR BLU GRN YEL ORG RED BRN WHT BLK...

Page 27: ...R USB DC BLOCK OK POWER CORD CONDENSATION FAN PRIMARY PCB SECONDARY PCB POUR BUTTON POUR BUTTON GPIO ICE DOOR TRIGGER VALVEHARN RIGHT VALVEHARN LEFT SBC USB A TO USB B DIO PCB POWER SUPPLY USB A MALE...

Page 28: ...SATION FAN PRIMARY PCB SECONDARY PCB GRN DC FAN AC OUT AC VOLT TO SUPPLY GRN BLU BLK DIO PCB BLK RED RED BLK BLK RED DENOTES DEFAULT 3 2 SW2 SWITCH 2 POSITION DOES NOT MATTER 4 ON LANCER PN 06 3289 01...

Page 29: ...29...

Page 30: ...A HOSHIZAKI COMPANY 6655 Lancer Boulevard San Antonio TX 78219 lancerworldwide com...

Reviews: