16. Tap the
Purge
tab at the bottom of the screen.
17. Tap the
Purge
buttons for both the plain water and the car-
bonated water modules.
Once the purge is activated, it will continue to dispense
product until it is deactivated. To deactivate the purge,
simply tap the
Purge
button again. Up to four modules
can be purged at one time. Once four modules are
selected, all other modules are grayed out and
cannot be selected.
NOTE
18. Once a steady flow of water is achieved, tap the
Purge
but-
ton again to deactivate the modules.
19. Make sure the pump deck is turned OFF before turning on
CO
2
.
20. Turn on CO
2
at the source then, using a screwdriver, adjust
the high pressure regulator at the source to 110 psi (0.758
MPa) then tighten locknut with wrench.
A. Regulator Adjustment Screw
B. Adjust to 110 psi (0.758 MPa)
C. Wrench
A
B
C
15. From the service menu tap the
Maintenance
button.
The manager’s access to the service menu allows
access the Sold Out screen, and the Time & Delays
screen.
NOTE
The pump deck has a 3 minute timeout feature. If the
timeout occurs, turn the deck OFF then ON by flipping
the switch on the control box.
NOTE
To check for CO
2
leaks, close the valve on the CO
2
cylinder and observe if the pressure to the system
drops with the cylinder valve closed for five minutes.
Open the cylinder valve after check.
NOTE
21. Adjust both of the low pressure regulators on the regulator
manifold to 75 psi (0.517 MPa) then tighten locknut with
wrench.
22. Activate each soda module until gas-out.
23. Plug in the remote carbonator pump deck, if not already
done so, and turn the switch to the ON position.
24. Activate each soda module until the carbonator pump comes
on. Release the button, allow carbonator to fill and stop.
Repeat this process until a steady flow of carbonated water
is achieved.
L’accès du gestionnaire au menu de service permet
accéder à l’écran Sold Out et à l’écran Time & Delays.
REMARQUE
The technician’s access to the service menu allows
access to the following menus: System, Lighting, Sold
Out, Time & Delays, Valve Configurations, Maintenance,
Data Management, Component Versions, Test Solenoids.
NOTE
L’accès du technicien au menu de service permet
d’accéder aux menus suivants: Système, Éclairage,
Épuisé, Temps et délais, Configurations des vannes,
Maintenance, Gestion des données, Versions des com-
posants, Solénoïdes de test
REMARQUE
Une fois la purge activée, elle continuera à distribuer
le produit jusqu’à ce qu’elle soit désactivée. Pour
désactiver la purge, appuyez simplement à nouveau
sur le bouton Purge. Jusqu’à quatre modules peuvent
être purgés à la fois. Une fois que quatre modules sont
sélectionnés, tous les autres modules sont grisés et ne
peuvent pas être sélectionnés.
REMARQUE
Un délai d’inactivité de 3 minutes est prévu pour le bloc de
pompes. Si ce délai est dépassé, mettre le bloc de pompes
à ARRÊT, puis à MARCHE à l’aide de l’interrupteur de la
boîte de commande.
NOTE