Figure 5
Syrup Purge Plug
B. VOLUMETRIC VALVE CLEANING AND SANITIZING PROCEDURES (CONTINUED)
3. Valve and System Sanitizing
The complete valve and dispenser system must be sanitized during initial installation.
Follow the manufacturer’s instructions when scheduling and conducting dispenser
sanitizing. The valve must be sanitized once every two weeks. The valve may remain
on the dispensing tower during the sanitizing process.
C. SYRUP PURGE PLUG (FIGURE 5)
1. The Syrup Purge Plug (PN 52-1912), places the valve
in continuous syrup side operation. The targeted uses
for the purge plug consist of priming the syrup line on
an initial Volumetric Valve install, and for cleaning and
sanitization of the syrup side of the dispensing unit.
2. Operation of the syrup purge plug is as follows:
NOTE:
With a standard 75 VA transformer, up to six (6)
Volumetric Valves can be operated in the syrup purge
mode simultaneously.
a. Turn off electrical power to all valves.
b. Install syrup purge plugs into the valve or valves to be primed or sanitized. The syrup
purge plug installs in the ten-pin connector of the Volumetric Valve circuit board.
c. Turn on electrical power to the valves. At this time, the syrup side of the valves will begin
continuous
operation.
d. When through with the priming or sanitization operation, syrup purge operation can be
stopped in either of two ways:
Method 1:
Turn off electrical power to all valves, remove syrup purge plugs from the valves.
Turn on electrical power to all valves. Tap valve lever or push button to ensure proper
operation of all valves.
Method 2:
Remove syrup purge plug from the valves while they are in purge
operation. In this case, the valve may continue in the purge mode for up to six (6)
seconds after removal of the plug (this is normal). Tap valve lever or push button to ensure
proper operation of all valves.
52-1912
SYRUP PURGE
!
CAUTION
FOLLOWING SANITIZATION, RINSE WITH END-USE PRODUCT UNTIL THERE IS NO AFTERTASTE. DO
NOT USE A FRESH WATER RINSE. THIS IS A NSF REQUIREMENT. RESIDUAL SANITIZING SOLUTION LEFT IN THE
SYSTEM CREATES A HEALTH HAZARD.
PRECAUCIÓN
DESPUÉS DE LA ESTERILIZACIÓN, ENJUAGUE CON EL PRODUCTO FINAL HASTA QUE
ELIMINAR EL SABOR QUE QUEDA. NO ENJUAGUE CON AGUA FRESCA. ÉSTA ES UNA EXIGENCIA DE NSF. SI
QUEDA SOLUCIÓN DE ESTERILIZACIÓN EN EL SISTEMA, GENERA UN PELIGRO PARA LA SALUD.
ATTENTION
DÉFENSE DE RINCER L’OUTIL À L’EAU FRAICHE IMMÉDIATEMENT APRÈS UN TRAITEMENT
SEPTIQUE.EN CAS DE APRÈS-GOÛT, NE PURGER AVEC LE PRODUIT FINAL UNE EXIGENCE NSF.
!
CAUTION
FOLLOWING SANITIZATION, RINSE WITH END-USE PRODUCT UNTIL THERE IS NO AFTERTASTE. DO
NOT USE A FRESH WATER RINSE. THIS IS A NSF REQUIREMENT. RESIDUAL SANITIZING SOLUTION LEFT IN THE
SYSTEM CREATES A HEALTH HAZARD.
PRECAUCIÓN
DESPUÉS DE LA ESTERILIZACIÓN, ENJUAGUE CON EL PRODUCTO FINAL HASTA QUE
ELIMINAR EL SABOR QUE QUEDA. NO ENJUAGUE CON AGUA FRESCA. ÉSTA ES UNA EXIGENCIA DE NSF. SI
QUEDA SOLUCIÓN DE ESTERILIZACIÓN EN EL SISTEMA, GENERA UN PELIGRO PARA LA SALUD.
ATTENTION
DÉFENSE DE RINCER L’OUTIL À L’EAU FRAICHE IMMÉDIATEMENT APRÈS UN TRAITEMENT
SEPTIQUE.EN CAS DE APRÈS-GOÛT, NE PURGER AVEC LE PRODUIT FINAL UNE EXIGENCE NSF.
20