TROUBLE
CAUSE
REMEDY
5.7 No product dispensed
A. Water and syrup shutoffs on mounting
block not fully open.
B. The key switch on an electric valve is
in the OFF position.
C. Cup lever arm or ID panel actuator on
electric valve is not actuating the switch.
D. Electric current not reaching valve.
E. Improper or inadequate water or syrup
supply.
F. Transformer Failure
A. Open shutoff fully.
B. Turn key switch to ON position.
C. Repair
D. Check electric current supplied to
valve. If current is adequate, check
solenoid coil and switch, and replace if
necessary.
E. Remove valve from mounting block
and open shutoffs slightly and check
water and syrup flow. If no flow, check
dispenser for freeze-up or other problems
F. Reset transformer circuit breaker. If
breaker trips again, refer to Seciton 5.23
5.8 Water only dispensed; no syrup; or
syrup only dispensed, no water
A. Water or syrup shutoff on mounting
block not fully open.
B. Improper or inadequate water or syrup
flow.
C. BIB supply too far from
dispenser.
D. CO2 pressure too low.
E. Stalled or inoperative BIB
pump
F. Kinked line.
A. Open shutoff fully.
B. Remove valve from mounting block,
open shutoffs slightly and check water
and syrup flow. If no flow, check
dispenser for freeze-up or other
problems. Ensure BIB connection is
engaged.
C. Check that BIB supply is within six (6)
feet of the dispenser.
D. Check the CO2 pressure to the pump
manifold to ensure it is between 70
and 80 PSI (0.550 MPA).
E. Check CO2 pressure and/or replace
pump.
F. Remove kink or replace line.
25