1.9 CONNECTING TO WATER SUPPLY - CARBONATED WATER INLET
NOTE:
Adhere to the WATER SUPPLY Warnings/Cautions, Page 9.
A. Using appropriate tubing and fittings, connect carbonated water supply line to water source.
DO NOT CONNECT TO CARBONATOR AT THIS TIME.
B. Flush water supply line thoroughly.
NOTE:
If the water source is above 50 PSIG (0.345 MPA), cut tubing assembly and install Water
Regulator Kit (PN 18-0253/02) as shown in kit instruction sheet.
C. Route tubing through hole in counter and through opening behind splash plate and connect to
carbonator pump using a flare seal washer (PN 05-0017). Use a back-up wrench to prevent
damage to carbonator pump.
D. Leave 12 inches (305 mm) of extra tubing length below the counter for servicing and moving
the dispenser.
E. Turn on water supply and check for leaks.
F. Using test gauge assembly (PN 22-0138), set regulator at a maximum of 50 PSIG (0.345 MPA).
1.10 CONNECTING TO WATER SUPPLY - PLAIN WATER INLET
NOTE:
Adhere to the WATER SUPPLY Warnings/Cautions, Page 9.
A. Using appropriate tubing and fittings, connect plain water supply line to water source.
DO NOT
CONNECT TO DISPENSER AT THIS TIME
B. Flush plain water supply line thoroughly.
C. Route tubing through hole in counter and through opening behind splash plate and connect to
check valve on plain water inlet (labeled “Water”). Use a back-up wrench to prevent damage to
the check valve or water line.
D. Leave 12 inches (305 mm) of extra tubing length below the counter for servicing and moving
the dispenser.
E. Turn on water supply and check for leaks.
1.11 CONNECTING THE CO2 SUPPLY
A. Verify the CO2 tank valve is in the closed position. Connect the high pressure CO2 regulator
assembly to CO2 cylinder. Use a new CO2 tank washer if regulator does not have built-in o-ring
seal.
B. Place CO2 cylinder upright in a cool service location (under counter, etc.), and secure it with a
safety
chain.
C. Using tubing and fittings from installation kit connect tubing assembly to tank mount regulator
using flare seal washer (PN 05-0011). Use a back-up wrench to prevent damage to regulator
assembly.
D. Route gas line through hole in counter and through opening behind the dispenser splash plate.
Leave 12 inches (305 mm) of extra tubing length below the counter for servicing and moving
the dispenser.
F. Remove the protective plug from the CO2 manifold (located on top of mini pumps on left side of
unit) and connect the CO2 supply line using a 1/4 inch elbow (supplied in installation kit.)
5
WARNING
DO NOT TURN ON THE CO2 SUPPLY AT THIS TIME.
ADVERTENCIA
NO CONECTE TODAVÍA LA ALIMENTACIÓN DE CO2.
AVERTISSEMENT
N’OUVREZ PAS L’ALIMENTATION EN CO2 À CE MOMENT.
G. If dispenser does not have built in syrup pumps, connect directly to the carbonator CO2 inlet
check
valve.
H. Attach a CO2 supply line from each of the figal syrup containers to the low pressure regulator
and pressurize the containers.
12