Technical Note

 

Date: 

Tuesday, 9 June 2020 

Applicable Equipment: 

Tintmaster Dispensers (TM280 / TM300) 

Subject: 

Start-up process following a prolonged idle period 

 

This is a guide to help  prepare the  Tintmaster Dispensers (TM280 / TM300) to normal operation  after a 
prolonged period of non-use. 
 
Before trying to dispense colorant, please follow the steps below: 
 

Tools 

 

Paper towel / cloth / wet wipes for cleaning and/or to remove dried colorants 

 

10 mm socket (to remove the side panels) 

 

Anti mould spray if appropriate 

 

Gloves and/or any other personal protective equipment recommended by site, employer, etc.  

 
Procedure 

1.

 

Press E-Stop button on the dispenser  

2.

 

Check if the brush is clean, and that there is correct amount of cleaning liquid (water / solvent) in the 
brush container  

3.

 

Open the canister lid one by one and check the colorant condition. If colorant is hardened, thickened 
or mould has grown, take appropriate actions. You may need to contact the colorant supplier / paint 
supplier for further instructions 

4.

 

Take off the side covers of the machine, and 

a.

 

Visually check the valve wiper and nozzle one by one.  

i.

 

Check to ensure the valve is returning to cover the nozzle. If not, the valve spring 
and/or wiper pad may be damaged. Replace them or you may need to consult with 
your service supplier 

ii.

 

Check to ensure that the valve wipers are clean. Remove any dried colorants 

b.

 

Clean the nozzles manually if you suspect colorant may have dried. Take off the nozzle one 
by one, wash with warm water, and place back onto the pump. IMPORTANT: Ensure to place 
the o-ring back into the nozzle. If o-rings are broken or damaged, you need to replace with 
new ones. 

c.

 

Visually check and ensure that each pump disk is in the correct height. You may find some 
pump disks are raised up, if so, then push them down to the correct height.  

d.

 

NOTE: You may need to close the covers, switch on the machine, turn the turn table to the 
different position to be able to access all pumps. For safety, close the side covers every time 
before switching on the machine  

e.

 

Close the side covers before you proceed to the next step 

5.

 

If dispenser is not connected to the power, connect to the power supply 

6.

 

Release the E-Stop button on the dispenser 