3.   CONNECTING TO ELECTRICAL SUPPLY
NOTE:

 In addition to the following, adhere to ELECTRICAL WARNINGS AND CAUTIONS, page 6.

NORTH AMERICAN UNITS REQUIREMENTS:

Plug the provided transformer (PN 

25-0069/01

) into the proper wall socket.

INTERNATIONAL TRANSFORMER (NOT PROVIDED) REQUIREMENTS:

Rated 50 VA or higher, primary voltage as required, and a Secondary Voltage 24VAC. Overcurrent and

surge protection is recommended. Connector wires for the transformer are included in the unit.

F

WARNING

 CHECK THE DISPENSER SERIAL NUMBER PLATE FOR CORRECT ELECTRICAL REQUIREMENTS 

OF UNIT. DO NOT PLUG INTO A WALL ELECTRICAL OUTLET UNLESS THE CURRENT SHOWN ON THE SERIAL 

NUMBER PLATE AGREES WITH LOCAL CURRENT AVAILABLE. THIS UNIT MUST BE PROPERLY ELECTRICALLY 

GROUNDED TO AVOID POSSIBLE FATAL ELECTRICAL SHOCK OR SERIOUS INJURY TO THE OPERATOR. THE 

POWER CORD HAS A THREE-PRONG GROUNDED PLUG. IF A THREE-HOLE GROUNDED ELECTRICAL OUTLET IS 

NOT AVAILABLE, USE AN APPROVED METHOD TO GROUND THE UNIT. FOLLOW ALL LOCAL ELECTRICAL CODES 

WHEN MAKING CONNECTIONS. EACH POWER SUPPLY MUST HAVE A SEPARATE ELECTRICAL CIRCUIT. DO NOT 

USE EXTENSION CORDS. DO NOT “GANG” TOGETHER WITH OTHER ELETRICAL DEVICES ON THE SAME 

OUTLET. THE KEYSWITCH DOES NOT DISABLE THE LINE VOLTAGE TO THE TRANSFORMER PRIMARY. ALWAYS 

DISCONNECT POWER TO THE DISPENSER BEFORE ATTEMPTING ANY INTERNAL MAINTENANCE. ONLY 

QUALIFIED PERSONNEL SHOULD SERVICE INTERNAL COMPONENTS OF ELECTRICAL CONTROL HOUSING. 

MAKE SURE THAT ALL WATER LINES ARE TIGHT AND UNITS ARE DRY BEFORE MAKING ANY ELECTRICAL 

CONNECTIONS!

ADVERTENCIA 

 VERIFIQUE LA PLACA CON EL NÚMERO DE SERIE DEL DISPENSADOR, DONDE ENCONTRARÁ 

LOS REQUISITOS ELÉCTRICOS CORRECTOS DE LA UNIDAD. NO ENCHUFE LA UNIDAD EN UN 

TOMACORRIENTE DE PARED A MENOS QUE LA CORRIENTE INDICADA EN LA PLACA CON EL NÚMERO DE 

SERIE CONCUERDE CON LA CORRIENTE LOCAL DISPONIBLE. ESTA UNIDAD DEBE ESTAR DEBIDAMENTE 

CONECTADO A TIERRA PARA EVITAR POSIBLES CHOQUES ELÉCTRICOS MORTALES O LESIONES GRAVES AL 

OPERADOR. LE BLOC D’ALIMENTATION DOIT ÊTRE MIS À LA TERRE ÉLECTRIQUEMENT CORRECTEMENT POUR 

ÉVITER DES BLESSURES GRAVES OU UNE DÉCHARGE ÉLECTRIQUE MORTELLE. LE CORDON D’ALIMENTATION 

A UNE FICHE À TROIS BRANCHES MISE À LA TERRE. SI AUCUNE PRISE DE COURANT ÉLECTRIQUE À TROIS 

TROUS N’EST DISPONIBLE, UTILISEZ UNE MÉTHODE APPROUVÉE POUR METTRE L’UNITÉ À LA TERRE. AL 

HACER LAS CONEXIONES, RESPETE TODOS LOS CÓDIGOS ELÉCTRICOS LOCALES. CADA DISPENSADOR 

DEBE TENER UN CIRCUITO ELÉCTRICO INDEPENDIENTE. NO USE EXTENSIONES CON ESTA UNIDAD. NO LA 

CONECTE JUNTO CON OTROS DISPOSITIVOS ELÉCTRICOS AL MISMO TOMACORRIENTE. EL INTERRUPTOR DE 

LLAVE NO CORTA EL VOLTAJE DE LÍNEA AL TRANSFORMADOR PRIMARIO. DESCONECTE SIEMPRE LA 

ALIMENTACIÓN ELÉCTRICA A LA UNIDAD PARA EVITAR LESIONES PERSONALES ANTES DE TRATAR DE 

REALIZAR TAREAS DE MANTENIMIENTO. EL SERVICIO DE LOS COMPONENTES INTERNOS DE LA CAJA DE 

CONTROL ELÉCTRICO DEBE CONFIARSE EXCLUSIVAMENTE A PERSONAL CALIFICADO. ASEGÚRESE DE QUE 

TODAS LAS LÍNEAS DE AGUA ESTÉN AJUSTADAS Y LAS UNIDADES ESTÉN SECAS 

ANTES DE HACER CONEXIONES ELÉCTRICAS.

EXIGENCES DE MISE À LA TERRE

 EXAMINEZ LA PLAQUE DE NUMÉRO DE SÉRIE DU DISTRIBUTEUR POUR 

CONNAÎTRE LES BONNES EXIGENCES EN MATIÈRE D’ÉLECTRICITÉ POUR L’APPAREIL. NE LE BRANCHEZ PAS 

À UNE PRISE ÉLECTRIQUE MURALE À MOINS QUE LE COURANT INDIQUÉ SUR LA PLAQUE DE NUMÉRO DE 

SÉRIE CORRESPONDE AU COURANT LOCAL DISPONIBLE. L’UNITÉ DOIT ÊTRE MISE À LA TERRE 

ÉLECTRIQUEMENT POUR ÉVITER UNE DÉCHARGE ÉLECTRIQUE MORTELLE OU DES BLESSURES GRAVES 

POSSIBLES À L’OPÉRATEUR. LE BLOC D’ALIMENTATION DOIT ÊTRE MIS À LA TERRE ÉLECTRIQUEMENT 

CORRECTEMENT POUR ÉVITER DES BLESSURES GRAVES OU UNE DÉCHARGE ÉLECTRIQUE MORTELLE. LE 

CORDON D’ALIMENTATION A UNE FICHE À TROIS BRANCHES MISE À LA TERRE. SI AUCUNE PRISE DE 

COURANT ÉLECTRIQUE À TROIS TROUS N’EST DISPONIBLE, UTILISEZ UNE MÉTHODE APPROUVÉE POUR 

METTRE L’UNITÉ À LA TERRE. RESPECTEZ TOUS LES CODES ÉLECTRIQUES LOCAUX LORSQUE VOUS FAITES 

DES CONNEXIONS. CHAQUE SOURCE D’ALIMENTATION DOIT AVOIR UN CIRCUIT ÉLECTRIQUE SÉPARÉ. 

N’UTILISEZ PAS DE CORDONS PROLONGATEURS. NE BRANCHEZ PAS PLUSIEURS APPAREILS ÉLECTRIQUES À 

LA MÊME PRISE DE COURANT. L’INTERRUPTEUR À CLÉ NE COUPE PAS LA TENSION SECTEUR AU 

TRANSFORMATEUR PRIMAIRE. DÉCONNECTEZ TOUJOURS L’ALIMENTATION EN ÉLECTRICITÉ À LA 

DISTRIBUTRICE AVANT DE FAIRE DE L’ENTRETIEN INTERNE. SEUL LE PERSONNEL QUALIFIÉ DEVRAIT FAIRE 

L’ENTRETIEN/LA RÉPARATION DES COMPOSANTS INTERNES DANS LE LOGEMENT DES COMMANDES 

ÉLECTRIQUES. ASSUREZ-VOUS QUE TOUTES LES CONDUITES D’EAU SONT ÉTANCHES ET QUE LES 

APPAREILS SONT SECS AVANT DE FAIRE DES CONNEXIONS ÉLECTRIQUES!

Summary of Contents for 85-3151R-VV

Page 1: ...1500 Technical Support Warranty 800 729 1550 custserv lancercorp com lancercorp com Manual PN 28 0883 03 DIGITAL RELEASE ONLY MAY 2013 FOR QUALIFIED INSTALLER ONLY UNICORN TOWER Operation Manual PN 28...

Page 2: ...1 CLEANING SANITIZING SOLUTIONS 15 4 2 DAILY CLEANING 15 4 3 WEEKLY CLEANING SANITIZING 16 4 4 CLEANING AND SANITIZING BEVERAGE COMPONENTS BAG IN BOX SYSTEMS 17 5 PROGRAMMING OVERVIEW 18 5 1 PROGRAMM...

Page 3: ...LECTRICAL REQUIREMENTS Refer to CONNECTING TO ELECTRICAL SUPPLY on pg 13 WEIGHT Shipping 35 lbs 15 88 kg Counter Weight 40 lbs 18 1 kg FITTINGS Soda Plain water inlet 1 4 barb Brand syrup inlets 1 4 b...

Page 4: ...any internal maintenance The resettable breaker switch should not be used as a substitute for unplugging the dispenser from the power source to service the unit Only qualified personnel should servic...

Page 5: ...sin superar el m ximo de 50 PSI 0 345 MPA La presi n de agua que supere los 50 PSI se debe reducir a 50 PSI 0 345 MPA con un regulador de presi n Use un filtro en la l nea de agua para evitar da os al...

Page 6: ...inimo 25 PSIG 0 172 MPA Maximo 50 PSIG 0 345 MPA En unidades sin regulador de presi n incorporado si la presi n del agua es superior a 50 PSIG 0 345 MPA se debe usar un regulador de presi n 3 Los enva...

Page 7: ...BIB Regulator Set BIB Connectors verify correct amount for syrup lineup BIB Syrup Boxes Remote Cooling Carbonation System THIS MANUAL APPLIES TO THE FOLLOWING UNITS 85 3151R 21 11111 00 TOWER UNICORN...

Page 8: ...ADA Standards for Accessible Design states that the maximum reach height from the floor should be no more than 48 if touch point is less than 10 from the front of the counter or a maximum of 46 if th...

Page 9: ...drip tray Fig 3b Position the font with the Selection Buttons and Nozzle above the Drip Tray 3 Route Ribbon Cable Wire Harnesses and Plumbing Lines through the nut Next thread nut on shank and tighten...

Page 10: ...nsure adequate slack remains for connection lines to accommodate sliding the Box forward for servicing 2 Secure the Mounting Bracket to bottom of counter with four screws Fig 5 3 Align the Junction Bo...

Page 11: ...e Unicorn Font to the appropriate connection in the Junction Box c Connect the Ribbon Cable PN 52 3346 to the Main Board PN 64 5048 space labeled J8 in the Junction Box d Connect the Power Wire Harnes...

Page 12: ...ource supplying soft water This will cause excessive foaming B JUNCTION BOX PLUMBING LINE CONNECTIONS FOR LFCV NOTE It is recommended that the that plumbing lines to font are routed out rear of Juncti...

Page 13: ...Junction Box Water Inlet and Outlets Insulate the tubing C DRAIN Route and connect drain tubing between font drip tray and facility drain Follow all local health and safety codes when performing this...

Page 14: ...E TROIS BRANCHES MISE LA TERRE SI AUCUNE PRISE DE COURANT LECTRIQUE TROIS TROUS N EST DISPONIBLE UTILISEZ UNE M THODE APPROUV E POUR METTRE L UNIT LA TERRE AL HACER LAS CONEXIONES RESPETE TODOS LOS C...

Page 15: ...g is thorough using clean potable water at a temperature of 90 to 110 degrees F Extended lengths of product lines may require additional cleaning solution SANITIZING SOLUTION Prepare sanitizing soluti...

Page 16: ...ZER IS USED DISSOLVE IT THOROUGHLY WITH HOT WATER PRIOR TO ADDING TO THE SYRUP SYSTEM ENSURE SANITIZING SOLUTION IS REMOVED FROM THE DISPENSER AS INSTRUCTED AVOID GETTING SANITIZING SOLUTION ON CIRCUI...

Page 17: ...ystem may be required H Following the instructions as described in 4 1 above mix appropriate amount of sanitizing solution in a clean container Place syrup inlet line in container filled with sanitizi...

Page 18: ...e of the circle Mode LED Red LED below the Size buttons Brand LED Green LEDs in each brand quadrant Water LED Green LED in the middle of the circle P C Pour Cancel depending on configuration activated...

Page 19: ...to choose between carbonated C or non carbonated rink n F Press or to raise or lower desired ratio G Press enter button to save the setting into the valve memory AFTER PROGRAMMING IS COMPLETE 5 2 CON...

Page 20: ...ging of water or syrup without shutting off the back block 1 If unit is in IDLE MODE without a selected Active Brand AND has not dispensed since unit was powered on the PURGE MODE can be accessed by p...

Page 21: ...the volume from each programming step to the total drink size When the portion is dispensed from idle mode the entire drink is dispensed without pauses If unit has an Active Brand selected Calibrated...

Page 22: ...adjust water flow control to 14oz in 8 seconds Adjust water module in clockwise to increase the flow or out counter clockwise to decrease the flow F With water volume correct turn on syrup brand supp...

Page 23: ...e A Plug in 24 volt power supply B Open mounting block shut offs C Replace touch panel D Check fuse or replace circuit board E1 Replace coil if resistance is open or shorted E2 Verify connectors are l...

Page 24: ...nsulation 8 ILLUSTRATIONS AND PARTS LISTINGS TOWER UNICORN T C PC CC LFCV SPARE PARTS LIST LIST 8 1 LFCV ELECTRONIC SPARE PARTS 24 8 2 LFCV NOZZLE SPARE PARTS 25 8 3 LFCV VALVE SPARE PARTS 26 8 4 WIRI...

Page 25: ...CTRONIC LFCV SPARE PARTS 4 3 2 1 25 Item Part No Description 1 52 3344 HARN LFCV THRU CNTR VAL UNICORN 2 52 3358 HARNESS BYPASS UNICORN 3 64 5048 PCB ASSY MAIN BOARD UNICORN 4 05 1678 STANDOFF PCB REV...

Page 26: ...ption 1 64 5057 PCB ASSY TOUCH PAD UNICORN W PORTION CONTROL 2 17 0647 01 SOLENOID 24 VDC 1 8 NPT 2WNC 3 05 2971 ELBOW qUICK CONNECT 1 4 X 1 8 4 02 0214 O RING 2 008 97 0999 5 81 0679 NOZZLE ASSY UNIC...

Page 27: ...0267 02 VALVE ASSY LFCV 2 0 SODA GRY S 4 05 1385 ELBOW 5 DOLE X 2 BARB PLS 5 02 0089 O RING 2 012 97 0999 6 19 0266 02 VALVE ASSY LFCV 2 0 SYR BLK SC 7 04 1089 SCR 10 32 RH PH SL 1 000 8 82 2317 01 BL...

Page 28: ...28 8 4 WIRING DIAGRAM LFCV...

Page 29: ...Part No Description 1 52 3381 HARNESS WATER MODULE VV RECIRC UNICORN 2 52 3359 HARN SOLENOID KIP VV UNICRN 3 52 3360 HARN SOLENOIDS VV UNICORN 4 52 3358 HARNESS BYPASS UNICORN 5 64 5048 02 PCB ASSY MA...

Page 30: ...109 97 0999 4 01 2762 FTG SODA OUTLET UNCRN 5 02 0005 O RING 2 010 97 0999 6 02 0214 O RING 2 008 97 0999 7 05 2929 FITTING INLET NOZZLE SYRUP 8 04 1639 SCREW 4 20X 250 IN PH PHILLIPS PLASTITIE 18 8...

Page 31: ...VALVE SPARE PARTS LIST Item Part No Description 5 02 0005 O RING 2 010 97 0999 6 05 1386 ELBOW 375 DOLE X 2 BARB PLS 7 19 0398 SYRUP MODULE VOL 1 5 3 0 8 04 1089 SCR 10 32 RH PH SL 1 000 9 82 2317 01...

Page 32: ...8 MISC SPARE VV PARTS LIST Item Part No Description 1 64 5057 PCB ASSY TOUCH PAD UNICORN W PORTION CONTROL 2 01 2757 FTG WYE 12ID UNCRN 3 01 2806 JG BULKHEAD CONNECTOR 3 8 S FIT X 3 8 S FIT 79000217 1...

Page 33: ...33 8 9 WIRING DIAGRAM VV...

Page 34: ...34 8 10 COUNTER CUTOUT TEMPLATE not to scale...

Page 35: ...35 NOTES...

Page 36: ...Lancer Corp 800 729 1500 Technical Support Warranty 800 729 1550 custserv lancercorp com lancercorp com...

Reviews: