1.5 PLUMBING LINE CONNECTIONS
A. CONNECTING TO WATER SUPPLY
1. Use a tube cutter to cut tubing. Tubing cut with a saw will result in plastic shavings that
could plug the flow controls in the dispensing valve.
2. Provide an adequate potable water supply. Water pipe connections and fixtures directly
connected to a potable water supply must be sized, installed, and maintained according
to federal, state, and local laws. An adequate potable water supply must be provided. It is
recommended that the supply shut-off is easily accessible. The water supply line must be at
least 3/8 inches (9.525 mm) pipe with a minimum of 20 PSI (0.317 MPA) line pressure, but
not exceeding a maximum of 50 PSI (0.345 MPA). Water pressure exceeding 50 PSI
(0.345 MPA) must be reduced to 50 PSI (0.345 MPA) with a pressure regulator. Use filter*
in the water line to avoid equipment damage and beverage off-taste.
* Filter of at least 100 mesh [100 strands per 25mm (one inch)] shall be installed
immediately upstream of all check valve type backflow preventers used for water supply
protection. The screen shall be accessible and removable for cleaning or replacement.
Check the water filter periodically, as required by local conditions. The water supply must
be protected by means of an air gap, a backflow prevention device (located upstream of
the CO2 injection system) or another approved method to comply with NSF standards. Do
not connect to a heated (hot) water source or a water source supplying soft water. This will
cause excessive foaming.
B. JUNCTION BOX PLUMBING LINE CONNECTIONS - FOR LFCV
NOTE:
It is recommended that the that plumbing lines to font are routed out rear of Junction Box.
1. Insert the syrup and water lines (from the Unicorn Font) into the appropriate syrup and
water outlets on the rear of the Junction Box. Refer to Fig 5.
2. There are 2 (two) 1/4” OD Recirculating Water lines, labeled RECIRC. Plug both into the
John Guest Bulkhead Connectors.
NOTE:
Either RECIRC line can plug into the top.
3. Use the small diameter insulation accordingly to cover all water and syrup tubing.
4. Secure all the fittings in place with the red locking clips.
C. JUNCTION BOX PLUMBING LINE CONNECTIONS - VOLUMETRIC
NOTE:
It is recommended that the that plumbing lines to font are routed out rear of Junction Box.
1. Insert the syrup and water lines (from the Unicorn Font) into the appropriate syrup and
water outlets on the rear of the Junction Box. Refer to Fig 5.
2. Connect the ‘H’ shaped water line to the John Guest Bulkhead Connectors.
NOTE:
Either
RECIRC line can plug into the top.
3. Secure all the fittings in place with the retainer clips.
S4 S4 S4
S3 S3 S3
S2 S2 S2
S1 S1 S1
Figure 9
!
WARNING
CHECK THE WATER FILTER PERIODICALLY, AS REQUIRED BY LOCAL CONDITIONS. IT IS THE
RESPONSIBILITY OF THE INSTALLER TO ENSURE COMPLIANCE.
ADVERTENCIA
VERIFIQUE PERIÓDICAMENTE EL FILTRO DE AGUA DE ACUERDO CON LAS CONDICIONES
IMPERANTES. ES RESPONSABILIDAD DEL INSTALADOR CUMPLIR CON ESTOS
REQUISITOS.
AVERTISSEMENT
VÉRIFIEZ LE FILTRE À EAU PÉRIODIQUEMENT, SELON LES EXIGENCES DES CONDITIONS
LOCALES. L’INSTALLATEUR EST RESPONSIBLE D’ASSURER LA CONFORMITÉ.
Summary of Contents for 85-3151R-VV
Page 28: ...28 8 4 WIRING DIAGRAM LFCV...
Page 33: ...33 8 9 WIRING DIAGRAM VV...
Page 34: ...34 8 10 COUNTER CUTOUT TEMPLATE not to scale...
Page 35: ...35 NOTES...