16
4.3 WEEKLY CLEANING AND SANITIZING
A. Disconnect power to the unit.
B. Following the instructions as described in 4.1 above,
mix appropriate amount of sanitizing solution in a clean
container. Place small portion of the cleaning solution in
a separate clean container (no less than 3 inches deep).
C. To remove the Nozzle (Fig 11) from the dispenser, grasp
the Nozzle and pull downward.
D. Submerge the Nozzle in the container with the smaller
portion of solution.
E. Place the Nozzle in the set aside portion of solution.
F. Grasp the Chrome Disks located on the right and left side of the dispenser head (Fig 11).
G. Rotate the Chrome Disks, slowly, in a counter-clockwise movement.
NOTE:
When facing unit,
the Left Disk will rotate towards the back (away from front). The Right Disk will rotate forward.
H. Stop rotating the disks when a square notch is visible on both the Left and Right side (Fig 12).
I. To remove the Handle, slowly pull the Handle up and away from the Unicorn dispenser.
) to gently clean the side of the dispenser head.
Refer to the arrows in Figure 13.
K. To reinstall the Handle, align the Set Pins with the notch on both sides of the dispenser.
Gently push the Handle into place.
L. Rotate the Chrome Disks back into place.
NOTE:
Verify
square notches are not visible to prevent accidental
Handle removal.
M. Use a clean cloth soaked in the cleaning solution to
clean the font and all exterior stainless steel surfaces.
N. Remove the Cup Rest. Wipe clean the Drip Tray and
Cup Rest. Replace Cup Rest.
O. Wipe clean all the splash areas.
P. Clean beverage valves as specified by the valve
manufacturer.
Figure 12
Figure 13
Notch
Cleaning
Brush
!
WARNING
IF A POWDER SANITIZER IS USED, DISSOLVE IT THOROUGHLY WITH HOT WATER PRIOR TO
ADDING TO THE SYRUP SYSTEM. ENSURE SANITIZING SOLUTION IS REMOVED FROM THE DISPENSER AS
INSTRUCTED. AVOID GETTING SANITIZING SOLUTION ON CIRCUIT BOARDS. DO NOT USE STRONG BLEACHES
OR DETERGENTS; THESE CAN DISCOLORAND CORRODE VARIOUS MATERIALS. DO NOT USE METAL
SCRAPERS, SHARP OBJECTS, STEEL WOOL, SCOURING PADS, ABRASIVES, OR SOLVENTS ON THE
DISPENSER. DO NOT USE HOT WATER ABOVE 140° F (60° C). THIS CAN DAMAGE THE DISPENSER.
ADVERTENCIA
SI SE USA UN HIGIENIZADOR EN POLVO, DISUÉLVALO BIEN EN AGUA ANTES DE AGREGARLO
AL SISTEMA DE CONCENTRADO. EL USO DE AGUA CALIENTE CONTRIBUYE A DISOLVER LOS HIGIENIZADORES
EN POLVO. ASEGÚRESE DE HABER ELIMINADO LA SOLUCIÓN DE ESTERILIZACIÓN DEL
DISPENSADOR DE ACUERDO CON LAS INSTRUCCIONES. LOS RESIDUOS DE LA SOLUCIÓN DE
ESTERILIZACIÓN REPRESENTAN UN PELIGRO PARA LA SALUD. EVITE QUE LA SOLUCIÓN DE ESTERILIZACIÓN
LLEGUE A LAS PLACAS DE CIRCUITOS. NO USE LAVANDINAS NI DETERGENTES QUE PODRÍAN QUITAR EL
COLOR Y CORROER DISTINTOS MATERIALES. NO USE RASPADORES METÁLICOS, OBJETOS FILOSOS, LANA
DE ACERO, ESTROPAJOS, ABRASIVOS NI SOLVENTES EN EL DISPENSADOR. NO USE AGUA CALIENTE A MÁS
DE 140 ºF (60 ºC). PODRÍA DAÑAR EL DISPENSADOR.
AVERTISSEMENT
AVANT L’INJECTION DANS LE SYSTÈME, IL FAUDRA QUE LA POUDRE SEPTIQUE SOIT
DISSOLUE ENTIÈREMENT DANS CHAUDE. L’EAU CHAUDE PERMETTRA UN MEILLEUR PROCÈS DE
DISSOLUTION. SUIVANT LES INSTRUCTIONS JOINTES, IL EST IMPÉRATIF QUE LA SOLUTION SEPTIQUE SOIT
ENTIÈREMENT ENLEVÉE. EVITEZ DE METTRE LA SOLUTION EN CONTACT AVEC LES CIRCUITS. N’UTILISEZ PAS
DE JAVELLISANTS OU DEDÉTERGENTS FORTS; CEUX-CI PEUVENT DÉCOLORER ET CORRODER DIVERS
MATÉRIAUX. N’UTILISEZ PAS DE RACLEURS EN MÉTAL, D’OBJETS POINTUS, DE LAINE D’ACIER, DE TAMPONS À
RÉCURER, D’ABRASIFS OU DE SOLVANTS SUR LE DISTRIBUTEUR. N’UTILISEZ PAS DE L’EAU CHAUDE DE PLUS
DE 140 DEGRÉS F (60 DEGRÉS C). CECI PEUT ENDOMMAGER LE DISTRIBUTEUR.