![background image](http://html1.mh-extra.com/html/lancer/85-3151r-vv/85-3151r-vv_operation-manual_3493594011.webp)
11
RIBBON CABLE
PN 52-3346
POWER WIRE HARNESS
PN 52-3348
LFCV VALVE HARNESS
PN 52-3344
J8
J1
J3
RIBBON CABLE
PN 52-3346
POWER WIRE HARNESS
PN 52-3348
VV KIP SOLENOID
PN 52-3359
J8
J1
J3
VV SOLENOID
PN 52-3360
J4
VV WATER
PN 52-3361
J5
Figure 7. LFCV
Figure 8. VV
D. JUNCTION BOX WIRING CONNECTIONS
1. CONNECT THE FOLLOWING, FOR BOTH Volumetric (VV) AND Lancer Flow Control
Valve (LFVC) MODELS:
a. The various Syrup Valve Harnesses from the Unicorn Font to the appropriate
connection in the Junction Box. Refer to the Wiring Diagram in the Junction Box.
b. Connect the Medallion Harness (PN
) from the Unicorn Font to the appropriate
connection in the Junction Box.
c. Connect the Ribbon Cable (PN 52-3346) to the Main Board (PN 64-5048) space
labeled J8 (in the Junction Box).
d. Connect the Power Wire Harness (PN
) to the Main Board space labeled J1.
NOTE: DO NOT CONNECT TO POWER SOURCE AT THIS TIME.
e. For VV Models, continue to Step 3.
For LFCV, continue to Step 2.
2. FOR LFCV MODELS ONLY:
a. Connect the LFCV Valve Harness (PN
) to the Selector Board space labeled J3.
b.
Continue
to
SECTION E. JUNCTION BOX PLUMBING LINE CONNECTIONS
3. FOR VV MODELS ONLY:
a. Connect the VV KIP Solenoid Harness (PN
) to the Main Board space labeled J3.
b. Connect the VV Solenoid Harness (PN
) to the Main Board space labeled J4.
c. Connect the VV Water Harness (PN
Summary of Contents for 85-3151R-VV
Page 28: ...28 8 4 WIRING DIAGRAM LFCV...
Page 33: ...33 8 9 WIRING DIAGRAM VV...
Page 34: ...34 8 10 COUNTER CUTOUT TEMPLATE not to scale...