![lancer 85-3151R-VV Operation Manual Download Page 20](http://html1.mh-extra.com/html/lancer/85-3151r-vv/85-3151r-vv_operation-manual_3493594020.webp)
20
C. IDLE MODE - TO DEACTIVATE A BRAND, WHILE THE UNIT IS NOT DISPENSING
PRODUCT
1. Select an inactive Brand. This will activate the selected Brand and deactivate the formerly
Active
Brand.
- To deactivate an Active Brand without selecting an inactive Brand, press the Active Brand
button for less than .35 seconds.
2. The Active brand automatically deactivates If the last recognized button press and the last
dispense were both at least 10 (ten) seconds prior.
D. MANUAL BRAND DISPENSE
1. Select the desired brand if it is inactive.
2. Pull and hold the handle to pour.
NOTE:
Depending on configuration, press and hold any brand while idle to pour.
E. WATER DISPENSE
1. To dispense water manually, Press and hold WAT button. Water LED will illuminate (Active
Brands automatically deactivate). If P/C or WAT buttons are not pressed, the Water LED
will turn off and dispense stops.
2. During a manual dispense, if 60 (sixty) seconds elapse, the Water LED turns off and the
dispense
stops.
F. PORTION CONTROL DISPENSE
1. Select a Brand.
2. Select a Size
NOTE:
Depending on configuration, pressing and holding the active brand will stop a portion
dispense in progress
G. PURGE MODE
NOTE:
Purge mode allows independent purging of water or syrup without shutting off the
back block.
1. If unit is in IDLE MODE without a selected Active Brand, AND has not dispensed since unit
was powered on, the PURGE MODE can be accessed by pressing and holding both
Brand 1 and Brand 4 buttons for 5 seconds.
2. During in Purge Mode, the Mode LED blinks at low duty cycle.
3. Press and hold WAT, to dispense water
4. Press and hold a Brand, to dispense syrup only
5. The unit will default to IDLE MODE automatically, if:
- the unit is NOT dispensing AND the last button press AND last dispense were both at
least 60 (sixty) seconds prior.
- the unit is NOT dispensing AND the handle is pulled.
H. TIMED POUR MODE
NOTE:
Timed pour mode assists flow rate calibration
If unit is in IDLE MODE without an Active Brand, and has not dispensed product since the unit was
powered on, the TIMED POUR MODE can be accessed by pressing and holding both Brand 1 and
Brand 2 buttons for 5 seconds.
1. During TIMED POUR MODE, the Mode LED blinks rapidly.
2. Press WAT, to dispense water.
3. Press a Brand, to dispense syrup only for the selected Brand
4. Dispense ends after 8 seconds
5. The unit will default to IDLE MODE automatically, if:
- the unit is NOT dispensing AND the last button press AND last dispense were both at least
60 (sixty) seconds prior, unit will return to IDLE MODE.
- the unit is NOT dispensing AND the handle is pulled, the unit returns to IDLE MODE.
Summary of Contents for 85-3151R-VV
Page 28: ...28 8 4 WIRING DIAGRAM LFCV...
Page 33: ...33 8 9 WIRING DIAGRAM VV...
Page 34: ...34 8 10 COUNTER CUTOUT TEMPLATE not to scale...