3.2.4 - RECIPES BY ANIMAL NUMBER WITH DIVIDED UNLOADS ONLY
1. When switching on the equipment automatically enters the Recipe Programming
Activity. The
PROG.
symbol lights up on the display and the [ recipe name ] message
appears.
If no name has been assigned to the Recipe, the [
REC
x
] message will appear,
where x indicates the progressive number of the Recipe selected.
2. To select the Recipe to be programmed or executed, press the
Recipe
key,
Recipe
and
e
or the
q
z
(
e
) keys.
3. To modify the Recipe Name (max. 6 alphanumeric characters) use the Alphanumeric
Writing (
2FN
).
4. Enable the Recipe to be programmed by Animal Number, by pressing the
Animal
key. The message [
N. HEADS
] will appear on the display along with the previously
programmed value. Select [
AUTO
] by pressing the
q
z
(
e
) keys; if the “0” value
appears on the display, to display [
AUTO
], press the
z
key one time only. Confirm
by pressing the
Animal
key or the
OK
key. The equipment will light up
g
next to the
symbol
���
and the
ANIMAL
symbol.
5. To copy a Recipe into another position in the Archive, select the Recipe and press
the
OK
key for 4 seconds. Release the key when, after the [
COPY
] message
appears, the display goes back to the [ recipe name ]. The display shows the
E
symbol to indicate that the Recipe Copy Function has been selected. Select the
Recipe in which the data is to be copied by pressing the
q
z
(
e
) keys.
Confirm by pressing the
OK
key for 2 seconds. The [
INSER.
] message will appear on
the display. To exit from the Function without copying the Recipe, press the
Clear
key
for 2 seconds.
6. To delete the data memorized in the Recipe (Name, Name and weight of the
Ingredients/Unloads, parameters) press the
Clear
key for 4 seconds.
The [
DELETE
] message and the Recipe Name will appear alternately on the display.
7. To program an Unload, an Ingredient must first be transformed into an Unload by
changing the Load Parameter into an Unload.
To modify the Parameter, select the Ingredient by pressing the
Ingr.
,
Ingr.
and
e
or
Block
and
Ingr.
keys. The Name and the programmed weight with a
resolution of 0.01 kg/lbs will appear alternately on the display. If no Name has been
assigned to the Ingredient, the [
ING
x
] message will appear on the display, where
x indicates the progressive number of the Ingredient selected. Press the
OK
key for
2 seconds. The [
UNLOAD
] message will appear on the display, the
LOAD
symbol will
turn off and the
UNLOAD
symbol will light up. To change the Parameter from Unload
to Load, repeat the same procedure.