COMPONENT MAINTENANCE MANUAL
AVIATION RECORDERS
Model FA5000
Initial Issue Page 806
Sep. 30/11
Fits and Clearances
23–70–40
Use or disclosure of information on this sheet is subject to
the restrictions on the cover page of this document.
Conditions
Standard
Description of Conducted Tests
Induced Susceptibility
19.0
DO-160F
19.3.1
19.3.2
19.3.3
19.3.4
Equipment tested to ZN
Radio Frequency Susceptibility
Conducted
Radiated
20.0
DO-160F
20.4
20.5
Equipment was tested to Category R
Equipment was tested to Category R
Threshold at 1.89GHz was 55V/m
Radio Frequency Emissions
Interference Voltages
Conducted
Radiated
21.0
DO-160F
21.4
21.5
Equipment was tested to Category M (exten-
ded)
Equipment was tested to Category M (exten-
ded)
Lightning Induced Transient
Susceptibility
22.0
DO-160F
Equipment was tested to Category A3J44
Lightning Direct Effects
23.0
DO-160F
This test was not required.
Icing
24.0
DO-160F
This test was not required.
Electrostatic Discharge
25.0
DO-160F
Equipment tested to Category A
Fire, Flammability
26.0
Equipment analyzed at Category C
*In the Fluids Susceptibility tests, material specimens were used.