6-3. Estimated operating time of the recommended battery (If using the MRS-104A-S)
The following curved line chart shows how the battery voltage under ambient temperatures relates to the continuous
operating time of the transmitter when using recommended batteries in an MRS-104A-S connected to 120 ohms of
bridge resistance for all four measurement channels (CH1 to CH4). Based on the curved lines in the chart below,
"Voltage level settings to light up" can be used to determine the remaining estimated operating time from the lighting
status of the LEDs.
(1)
In case of CR2
Transmitter model name
MRS-104A-S
Bridge resistance
120 ohm
Battery type
Lithium
Manufacturer
Panasonic
Battery model name
CR2
Number of batteries
1
2.1
2.2
2.3
2.4
2.5
2.6
2.7
2.8
2.9
3
3.1
3.2
3.3
0
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
T
ra
n
smi
tt
e
r
su
pp
ly
v
o
lt
ag
e
v
al
u
e
(V
)
Continuous operating time of the transmitter(hours)
Relation Voltage and continuous operating time depending on the ambient temp.
-25℃
-5℃
+23℃
+75℃
LEDs for
monitoring
Tx.-Battery
Voltage
●●●
●●
●
●
●●
●●●
Voltage level settings to light up
Remaining
estimated operating time
(ambient temperature at +23°C)
Lighting status of LEDs
Voltage setting value
●●
●
2.70 V
Approx.3.2 hours
●
●●
2.60 V
Approx.1.9 hours
●●●
2.50 V
Approx.1.2 hours
Summary of Contents for MRS-100 Series
Page 74: ...73 8 7 OUTSIDE DRAWING 8 7 1 MRS 114A 4ch Receiver ...
Page 75: ...74 8 7 2 MRS 104A S 4 ch Strain Transmtter ...
Page 76: ...75 8 7 3 MRS 101A S 1ch Strain Transmitter ...
Page 77: ...76 8 7 4 MRS 101A SE 1ch Strain Transmitter EXT Antenna ...
Page 78: ...77 8 7 5 MRS 101A V 1ch Voltage Transmitter ...
Page 79: ...78 8 7 6 DA DB 05RP SMA 08 High gain dipole antenna ...