![kymati KY-LOC 1D.02.01 User Manual Download Page 79](http://html1.mh-extra.com/html/kymati/ky-loc-1d-02-01/ky-loc-1d-02-01_user-manual_2014862079.webp)
This document is the property of KYMATI GmbH and must not be copied or disclosed without its written authorisation.
- KYMATI GmbH – 2021
KY.MAN.0105 (6.0)
KY-LOC 1D.02.01 User Manual
Doc.- No.: KY.MAN.0105
Version:
6.0
Date:
14.12.2021
Page:
79 of 83
12
Technical Data
12.1
KY-LOC 1D.02.01
Parameter
Value / Description
Range 1)
2m ≤ x ≤ 500 m
Antenna opening angle
horizontal ± 30°, vertical ± 10°
Repeat accuracy of measurement
typ. ± 15mm
Absolute distance accuracy
typ. ± 50mm
Update rate
up to 20 Hz (single side data connection)
Data transfer parallel to measurement
up to 1 kbit/s
Weight
1060 g (without support bracket)
Dimensions (LxWxD)
138 x 138 x 43mm
Power supply
9 ... 36 V DC or PoE
Power consumption
3W typ. / 5W (max.)
Frequency band
61 ... 61,5 GHz (ISM band)
Interfaces
Ethernet (100Base-Tx) - M12, 8 Pin, X-coded
RS 485 - M12, 5 Pin, A-coded
Trigger out
Amplitude 5V, CMOS, max frequency 1 kHz
Ingression Protection
(DIN EN 60529)
IP66, IP66K and IP68 24h diving at 1m (with
connected plugs or caps)
Operating temperature
(DIN EN 600068-2-1 & DIN EN 600068-2-2)
-40 ... +70 °C / -40 ... 158 F
Vibration & Shock
(DIN EN 600068-2-64 & DIN EN 600068-2-27)
Wideband noise 8h in all axis / half sine shocks
25g, 6ms 1.000 shocks / 6.000 shocks in
moving direction
EMC Compliance
EN 305 550 v2.1.0
The equipment is classified as Short-Range
Devices (SRD); Radio equipment to be used in
the 40 GHz to 246 GHz frequency range
EMC Compliance
EN 301 498-3 V2.11
The equipment fulfils the Electromagnetic
Compatibility
(EMC)
standard
for
radio
equipment and services; Part 1: Common
technical requirements
Radio emissions
EN 62311:2008
Assessment of electronic and electrical
equipment
related
to
human
exposure
restrictions for electromagnetic fields (0 Hz -
300 GHz)
Product Safety
EN 62368-1:2014
Audio/video, information and communication
technology equipment – Part 1: Safety
requirements
1)
Max. range depending on radio regulations applicable
2)
currently not supported in SW
Table 5: Technical Data KY-LOC 1D.02.01
12.2
KY-XTRA B.10.01
The KY-XTRA B.10.01 Switching Device is currently based on a Siemens LOGO! PLC.
It receives ModBus TCP coil messages from the KY-LOC 1D.02.01.