4.4
Power Supply
The sensor shall be powered with either a DC power supply via the X1 connector or via X2
connector (PoE - 802.3af) or plugging both is also allowed.
The power supply for the sensor must comply with the
ES1 limits and the voltage range stated in the datasheet.
The sensor is protected with a reverse polarity circuit to
avoid damages. In case there is a wrong polarity the
power LED will not illuminate, and the user must remove
the power immediately.
4.5
Connectors
The sensor has 2 x M12 connectors located on the bottom side of the device. To avoid faulty
connection the connectors are coded differently and on top female / male.
Figure 11: Bottom side X1 (DC/RS-485 connector) & X2 (Ethernet / PoE connector)
X1: DC/RS-485 connector:
Connector type: M12 according to IEC
61076-2 -101, 102 & 109
, 5 pin, male, A-coding,
material: Zinc Die Cast (default) or 1404 Steel (possible on customer request)
Figure 12: Connector X1 pin diagram (front view of male connector with pin numbers)
X1
X2