Appendix: Description of the Six Light Panel
KVAL Operation Manual
3-30
Appendix: Description of the Six Light Panel
The six lights on this panel in8
dictate the status of the power-up of the system. Each machine has this panel.
The Sequence the lights activate is as follows:
Sequence Order
Light Designation
Description
1
Control Power
This light illuminates when the Control Transformer turned
on and the power is working on secondary side-of trans-
former
2
Overload Relay
Checks the Overload Relay in the E-Box. In some
cases, this circuit is jumped. In these cases it should
always light when the Control Power turns on.
3
E-Stop
All gates are closed and the E-stops are not activated when
this light is on.
4
Stop
This light will be on if Machine Stop button is deactivated.
5
Start
This light will be on once the Machine Start button is
pressed and the ACR Relay is latched.
6
24VDC
This light comes on once the ACR is latch and the 24VDC
power Supply is working
Control Power
First
Overload Relay
Second
E-Stop
Third
24VDC –
Sixth
Stop –
Fourth
Start –
Fifth
Summary of Contents for DL-NCD
Page 10: ...KVAL DL NCD Operation Manual Table of Contents ...
Page 28: ...How to Download the Service Application KVAL Operation Manual 1 18 ...
Page 30: ...Safety Sign Off Sheet KVAL Operation Manual 1 20 ...
Page 62: ...About the LiteCutout Feature Detail KVAL Operation Manual 2 32 ...
Page 94: ...Appendix About Backing up the Data KVAL Operation Manual 3 32 ...
Page 118: ...Appendix Servo Motor Drive Assembly Locations KVAL Operation Manual 4 24 ...
Page 139: ...About the Electrical Panels KVAL Operation Manual 5 21 I ...
Page 142: ......
Page 143: ......