About Manual Tool Changer Control
This routine aids in ensuring the tool pick up and drop off locations between the
Cutter Head Tool Holde
r and
Tool Holder Rack
are matched up.
When activated, the
Cutter Head
is moved in repeatable steps toward and away from
the
Tool Holder
. At these step intervals, the operator establishes the distance between
the
Tool Holder
and
Tool Rack
tool position.
With the distance information, the operator uses the
Tool Holder Calibration
routine
(under the
Calibration Tab
) to calibrate precise tool pick up and drop off.
Note:
This mode can be used to perform a quick visual during production or as a
calibration tool.
Note:
In normal production the
Step Mode
can be ON or OFF. No interference with
production will occur.
About the DL-NCD Manual Servo Control Screen
KVAL Operation Manual
3-18
Process
Note:
If calibrating, calibrating one tool will calibrate all tools. For calibration infor-
mation,
see “Step 6: Calibrate the Tool Holder” on page 4-17.
This should be a two person operation with one at the
Operator Station
and one at the
Tool Holder Rack
. Each step is displayed in the
Status Message Box.
1.
Select the Step Mode button to turn it ON.
2.
Select the desired tool in the
Select Tool
section.
3.
Step forward or backward using the
Step Rev
and
Step Fwd Buttons.
Observe the
actions and locations of the
Tool Holder
in relation to the
Tool Rack
.
Step Mode Off
Status Message Box
ON/ OFF and Step Control
Select Tool
Status Message Box
FIGURE 3-3.
Manual Tool Changer Screen
Summary of Contents for DL-NCD
Page 10: ...KVAL DL NCD Operation Manual Table of Contents ...
Page 28: ...How to Download the Service Application KVAL Operation Manual 1 18 ...
Page 30: ...Safety Sign Off Sheet KVAL Operation Manual 1 20 ...
Page 62: ...About the LiteCutout Feature Detail KVAL Operation Manual 2 32 ...
Page 94: ...Appendix About Backing up the Data KVAL Operation Manual 3 32 ...
Page 118: ...Appendix Servo Motor Drive Assembly Locations KVAL Operation Manual 4 24 ...
Page 139: ...About the Electrical Panels KVAL Operation Manual 5 21 I ...
Page 142: ......
Page 143: ......