About the Main Control Screen
KVAL Operation Manual
3-12
About the Main Control Screen
Select the
Main Control Tab
. At the Main Screen, control the all the operations of the machine to
process a door.
FIGURE 3-1.
Main Screen of DL-NCD
About the Main Control Section
Home Machine
This button starts the home sequence on the
machine, which scans to find a physical reference
point on the frame. When this point is found, the
position is stored and then used to calculate the
location of all moves during the machine process.
The home sequence must be performed every
time the machine is powered up or reset.
Reset Machine
If a fault occurs that cannot be cleared, press the
Reset Machine
button. This button will reset the
machine to the start position. Press the
Home
button
after resetting the machine