Step 4: Calibrate the Lock Edge Probe (Option)
KVAL Operation Manual
4-14
Step 4: Calibrate the Lock Edge Probe (Option)
The
Lock Edge Drill
is an machine option that routes a lock on the door edge. This section focuses
on the
Edge Probe Calibration
. For instructions about entering calibration data,
Calibration Data” on page 4-6.
Lock Edge Probe
At the
Calibration Screen
, select
Door Stops and Probes
to display the calibration menu.
Before Probe Depth Calibration
Before calibrating the Lock Probe depth (
Z-Axis
) verify the
X-Axis
and
Y-Axis
.
This is a visual test.
Run a Door Job. Check the Depth
Probe Pad position as it touches the
door edge. Pad on probe should
cover at least 50% of the door edge.
+
X
+
Y
-
X
-
Y
Probe Pad