Service and maintenance
Fig. 24: Replace the heating element
ü
Slide in the spare heating element.
a) Align the groove of the heating element [1] with the marking in the soldering
iron [2].
b) Align the heating element exactly parallel to the soldering iron.
c) Gently push the heating element in carefully and slowly until it stops. If the
heating element cannot slide in easily, do not press with greater force, but re-
position it!
d) Re-install the soldering tip.
7.2.3
Resetting the soldering station with the reset key
If connection problems occur between the “Ersa TRACE Cockpit” web app and the
soldering station that cannot be remedied, resetting the soldering station to the
factory settings is recommended.
The default settings are described in chapter Defaults [
Resetting the soldering station
ü
Switch off the soldering station.
ü
Remove the soldering iron cable
ü
Connect the mains plug.
a) If any, disconnect the optional LAN cable.
b) Carefully turn the soldering station over so that the bottom side is facing up-
wards. When doing so, beware of the connected mains cable.
c) Hold down the reset button [12] (see Fig. 25) on the underside with a suitable
object (e.g. paper clip). Do not use a pointed object.
Ersa GmbH
3BA00252-01 | Rev. 1
40
Summary of Contents for i-CON TRACE