Service and maintenance
Fig. 23: Replacing the fuse
b) Remove the fuse holder and replace the “0.8 A slow blowing” fuse for the 230
V variant, or the “1.6 A slow blowing” one for the 115 V variant in the holder.
c) Re-install the fuse holder and close the compartment.
Note that a defective fuse may also indicate a deeper cause of error. If replacing
the fuse does not eliminate the error and no solution can be found in the Error
treatment [
38] chapter, contact Ersa Service by e-mail at:
.
7.2.2
Changing the heating element
CAUTION
Risk of burns!
Only change the heating element when both the soldering tip and
the heating element are cold!
Before changing the heating element, switch off the soldering station and allow
the soldering tip and the heating element to cool down!
a) Remove the soldering tip.
b) Pull the heating element out by hand.
Ersa GmbH