Commissioning
d) Insert the dry cleaner; Fig. 7 shows the recommended position.
Fig. 8: Plugging in the soldering iron
e) Fig. 8 left: Insert the plug of the soldering iron [1] into the soldering iron socket
at the soldering station [2]. When doing so, align the plug anti-rotation device
with the lower recess in the socket, see arrow.
f) Fig. 8 right: Align the recess of the union nut on the soldering iron plug [3] up-
wards. Then press the union nut [4] onto the plug and lock it by turning it 90
degree clockwise.
g) Connect the mains cable to the relevant connector on the soldering station
and the mains socket.
WARNING
Danger of fire due to covered ventilation slots!
a) Do not place the supporting stand on the soldering station! Never cover the
ventilation slots to avoid overheating!
Ersa GmbH
3BA00252-01 | Rev. 1
21
Summary of Contents for i-CON TRACE