Service and maintenance
7.
Service and maintenance
7.1
Error messages and error codes
The “Ersa TRACE Cockpit” web app shows errors such as an error code with an info
message. The SERVICE LED on the soldering station shows the error status. Read
more about this in Chapter LED signals [SERVICE]. After the error has been elimin-
ated and acknowledged, the connected soldering tool will be heated again.
List of error codes
Error message
Cause
Remedy
[Soldering station calibra-
tion]
Station is no longer calibrated Have factory calibration per-
formed
[Ambient temperature
sensor]
Temperature sensor measure
value not OK
Have soldering tool and solder-
ing station inspected
[No HE contact] /
[TS defective]
Heating element not correctly
installed / Error in temperat-
ure sensor
Install the heating element cor-
rectly, have the soldering tool
checked
[HE defective]
Heating element defective
Check the heating element,
check the soldering station
[Data loss!]
Parameter/configuration data
corrupted
Switch off the soldering station.
Reset as described in Chap. Re-
setting the soldering station with
the reset key [
[HE short circuit]
Heating element short-cir-
cuited
Replace the heating element
[Soldering tool calibration] Soldering tool is no longer cal-
ibrated
Have factory calibration per-
formed
[Mains frequency]
Mains frequency outside the
frequency range (± 10%)
Check mains frequency
[Overload protection]
Soldering station overloaded
Let the soldering station cool
down