10
INSTRUMENT PANEL AND CONTROLS
C
Liquid Crystal Display
No.
Message
Description
Refer-
ence
page
(1)
Displays "F", "R" or "N".
"F" is displayed when forward operation is selected with the shuttle lever.
"R" is displayed when reverse operation is selected.
("N" is displayed when the lever is in the neutral position.)
37
(2)
AUTO MODE (Automatic speed change)
Lights up when Travel mode or Field mode is selected.
Turns off when Travel mode and Field mode are not selected.
51
(3)
Displays "1" - "8" or "E".
Displays the number of the Power shift ratios that was selected with the Up-shift/Down-
shift button. "E" appears in case of gear shift error.
35
(4)
Displays "L", "M", "H", "C",
or "N".
Displays the position of the range gear shift that was selected with the Power shift/Range
shift lever. "C" appears when the creep speed is selected (option).
35
(5)
(6)
Light up when the Rev-limiter control has been set.
(Display flashes when the engine speed is at or below the set speed.)
47
(6)
Lights up when the RPM dual memory has been set.
47
(7)
Depending on the settings, the below messages are displayed.
1. Elapsed time (hour meter) 4. Maximum engine speed that is set by the
2. Trip time Rev- limiter control
3. Engine speed that is set in memory 5. Failure information or other information
41
(8)
TRIP
Lights up when trip time mode is selected.
41
(9)
Displays "h", "A", "B", or
"L".
"h" is displayed when the hour meter or trip time is selected.
"A" or "B" is displayed when the RPM dual memory is set.
"L" is displayed when the Rev-limiter control has been set.
41
47
47
(10)
Displays "0" - "99".
Digital display of the lift arm height.
---