5 Installation at Site
22 of 96
Magnochem-Bloc
CAUTION
Neither mounting plate nor foundation rails must be set in concrete.
5.3.1 Installation without foundation
1
4
Fig. 6:
Adjusting the levelling elements
1, 3
Locknut
2
Adjusting nut
4
Machine mount
ü
The installation surface has the required strength and characteristics.
1. Position the pump set on the machine mounts (4) and align it with the help of a
spirit level (on the shaft/discharge nozzle).
2. To adjust any differences in height, loosen the locknuts (1, 3) of the machine
mounts (4).
3. Turn the adjusting nut (2) until any differences in height have been
compensated.
4. Re-tighten the locknuts (1, 3) at the machine mounts (4).