5 Installation at Site
25 of 96
Magnochem-Bloc
For the pump set to be primed and vented completely, an external circulation line
must be routed from the discharge nozzle or discharge line to the rotor space. Take
into account the following requirements when installing the external circulation line:
1. Run the external circulation line (a) from the discharge nozzle or discharge line
to the rotor space; fit a check valve (4a).
2. For external fluid supply, connect the circulation line (b) to a flushing system; fit
a check valve (4b).
NOTE
The check valve will prevent the fluid handled from flowing back into the flushing
system.
5.4.2 Permissible forces and moments at the pump nozzles
F
z
F
y
F
x
F
x
F
y
F
z
F
x
F
y
F
z
M
z
M
y
M
x
Fig. 9:
Forces and moments
at the pump nozzles
The data on forces and moments apply to static piping loads only. If the limits are
exceeded, they must be checked and verified.
If a computerised strength analysis is required, values are available on request only.
The values are only applicable if the pump is installed on a completely grouted
baseplate and bolted to a rigid and level foundation.
Table 7:
Forces and moments at the pump nozzles for material variant C (1.4408 / A743 GR CF8M)
Size
Suction nozzle
Discharge nozzle
DN
F
x
[N]
F
y
[N]
F
z
[N]
∑F
[N]
M
x
[Nm]
M
y
[Nm]
M
z
[Nm]
DN
F
x
[N]
F
y
[N]
F
z
[N]
∑F
[N]
M
x
[Nm]
M
y
[Nm]
M
z
[Nm]
040-025-160
40
970
780
650
1404
845
585
683
25
490
455
600
898
370
390
455
040-025-200
40
970
780
650
1404
845
585
683
25
460
455
600
898
370
390
455
050-032-250.1
50
1240
1010
878
1824
910
650
748
32
650
555
780
1157
715
490
555
050-032-125.1
50
1240
1010
878
1824
910
650
748
32
650
555
780
1157
715
490
555
050-032-160.1
50
1240
1010
878
1824
910
650
748
32
650
555
780
1157
715
490
555
050-032-200.1
50
1240
1010
878
1824
910
650
748
32
650
555
780
1157
715
490
555
050-032-125
50
1240
1010
878
1824
910
650
748
32
650
555
780
1157
715
490
555
050-032-160
50
1240
1010
878
1824
910
650
748
32
650
555
780
1157
715
490
555
050-032-200
50
1240
1010
878
1824
910
650
748
32
650
555
780
1157
715
490
555
050-032-250
50
1240
1010
878
1824
910
650
748
32
650
555
780
1157
715
490
555
065-040-125
65
1600
1300
1105
2339
1050
715
780
40
780
650
1000
1425
845
585
685
065-040-160
65
1600
1300
1105
2339
1050
715
780
40
780
650
1000
1425
845
585
685
065-040-160.1
65
1600
1300
1105
2339
1050
715
780
40
780
650
1000
1425
845
585
685
065-040-250.1
65
1600
1300
1105
2339
1050
715
780
40
780
650
1000
1425
845
585
685
065-040-200
65
1600
1300
1105
2339
1050
715
780
40
780
650
1000
1425
845
585
685
065-040-250
65
1600
1300
1105
2339
1050
715
780
40
780
650
1000
1425
845
585
685
065-040-315
65
1600
1300
1105
2339
1050
715
780
40
780
650
1000
1425
845
585
685
080-050-315.1
80
2000
1550
1333
2860
1330
748
1010
50
1000
880
1250
1827
910
650
750
080-050-125
80
2000
1550
1333
2860
1330
748
1010
50
1000
880
1250
1827
910
650
750
080-050-160
80
2000
1550
1333
2860
1330
748
1010
50
1000
880
1250
1827
910
650
750
080-050-200
80
2000
1550
1333
2860
1330
748
1010
50
1000
880
1250
1827
910
650
750
080-050-250
80
2000
1550
1333
2860
1330
748
1010
50
1000
880
1250
1827
910
650
750
080-050-315
80
2000
1550
1333
2860
1330
748
1010
50
1000
880
1250
1827
910
650
750
100-065-125
100
2500
1950
1755
3624
1850
900
1400
65
1300
1105
1600
2339
1050
715
790
100-065-160
100
2500
1950
1755
3624
1850
900
1400
65
1300
1105
1600
2339
1050
715
790
100-065-200
100
2500
1950
1755
3624
1850
900
1400
65
1300
1105
1600
2339
1050
715
790
100-065-250
100
2500
1950
1755
3624
1850
900
1400
65
1300
1105
1600
2339
1050
715
790
100-065-315
100
2500
1950
1755
3624
1850
900
1400
65
1300
1105
1600
2339
1050
715
790
Summary of Contents for Magnochem-Bloc
Page 1: ...Mag drive Pump Magnochem Bloc Installation Operating Manual...
Page 93: ......
Page 94: ......
Page 95: ......