5 Installation at Site
26 of 96
Magnochem-Bloc
Size
Suction nozzle
Discharge nozzle
DN
F
x
[N]
F
y
[N]
F
z
[N]
∑F
[N]
M
x
[Nm]
M
y
[Nm]
M
z
[Nm]
DN
F
x
[N]
F
y
[N]
F
z
[N]
∑F
[N]
M
x
[Nm]
M
y
[Nm]
M
z
[Nm]
125-080-160
125
3400
2700
2200
4867
2550
1250
1950
80
1550
1335
1950
2826
1350
750
1000
125-080-200
125
3400
2700
2200
4867
2550
1250
1950
80
1550
1335
1950
2826
1350
750
1000
125-080-250
125
3400
2700
2200
4867
2550
1250
1950
80
1550
1335
1950
2826
1350
750
1000
125-080-315
125
3400
2700
2200
4867
2550
1250
1950
80
1550
1335
1950
2826
1350
750
1000
125-080-400
125
3400
2700
2200
4867
2550
1250
1950
80
1550
1335
1950
2826
1350
750
1000
125-100-160
125
3400
2700
2200
4867
2550
1250
1950
100
2000
1755
2500
3651
1850
900
1400
125-100-200
125
3400
2700
2200
4867
2550
1250
1950
100
2000
1755
2500
3651
1850
900
1400
125-100-250
125
3400
2700
2200
4867
2550
1250
1950
100
2000
1755
2500
3651
1850
900
1400
125-100-315
125
3400
2700
2200
4867
2550
1250
1950
100
2000
1755
2500
3651
1850
900
1400
125-100-400
125
3400
2700
2200
4867
2550
1250
1950
100
2000
1755
2500
3651
1850
900
1400
150-125-200
150
4300
3450
2850
6206
3200
1600
2450
125
2700
2200
3400
4867
2550
1300
1900
150-125-250
150
4300
3450
2850
6206
3200
1600
2450
125
2700
2200
3400
4867
2550
1300
1900
150-125-315
150
4300
3450
2850
6206
3200
1600
2450
125
2700
2200
3400
4867
2550
1300
1900
150-125-400
150
4300
3450
2850
6206
3200
1600
2450
125
2700
2200
3400
4867
2550
1300
1900
200-150-200
200
6750
5250
4300
9572
4850
2450
3550
150
3450
2850
4300
6206
3150
1600
2450
200-150-250
200
6750
5250
4300
9572
4850
2450
3550
150
3450
2850
4300
6206
3150
1600
2450
C, V
E, D
Y
0,6
0,7
0,8
0,9
1
1,2
0
50
100
150
200
250
300
400
°C
350
1,1
Correction coefficient
Fig. 10:
Temperature correction diagram for "C, D, E, V or Y variants" (1.4408 /
A743 GR CF8M)
5.4.3 Auxiliary connections
DANGER
Risk of potentially explosive atmosphere by mixing of incompatible fluids in the
auxiliary piping
Risk of burns!
Explosion hazard!
▷
Make sure that the barrier fluid or quench liquid are compatible with the fluid
handled.