7 Servicing/Maintenance
59 of 96
Magnochem-Bloc
7.5 Reassembling the pump set
7.5.1 General information/Safety regulations
DANGER
Strong magnetic field in the area of the magnetic coupling or the individual
magnets
Danger of death for persons with pacemaker!
Interference with magnetic data carriers, electronic devices, components and
instruments!
Uncontrolled magnetic attraction forces between magnet-equipped components,
tools or similar!
▷
Keep a safety distance of at least 0.3 m.
▷
Also observe the additional instructions. (
DANGER
Wrong selection of motor
Explosion hazard!
▷
Use an original motor or a motor of identical design from the same
manufacturer.
▷
The permissible temperature limits at the motor flange and motor shaft must
be higher than the temperatures generated by the pump. (Contact KSB for
temperatures).
DANGER
Leaks and/or corrosion damage on monitoring systems
No fault indications!
Leakage of fluid handled!
▷
Never install damaged or corroded monitoring systems in the pump.
▷
Check monitoring systems for damage and correct function prior to installation.
WARNING
Improper lifting/moving of heavy assemblies or components
Personal injury and damage to property!
▷
Use suitable transport devices, lifting equipment and lifting tackle to move
heavy assemblies or components.
WARNING
Collision between bearing bracket lantern and containment shroud or bearing
bracket lantern and bearing bracket/intermediate piece due to magnetic forces
Damage to magnets and bearings!
Risk of injury!
▷
Strictly follow the instructions for reassembly.