8 Trouble-shooting
78 of 96
Magnochem-Bloc
A B C D E
F Possible causes
Remedy
10)
-
✘ ✘
-
-
- Speed is too high.
Reduce speed (turbine, I.C. engine).
11)12)
✘
-
-
-
✘
- Wear of internal components
Replace worn components by new ones.
-
-
-
✘
-
- Use of unsuitable materials
Change the material combination.
-
-
-
✘
-
- Connection bolts and screw plugs have
loosened.
Re-tighten.
Fit new sealing elements.
-
-
-
-
-
✘
Lack of cooling liquid or dirty cooling chamber Increase cooling liquid quantity.
Clean out cooling chamber.
Purify/clean cooling liquid.
-
-
-
✘
-
- Dismantle to find out.
Repair necessary.
-
✘
-
-
✘
- Pump is warped or sympathetic vibrations in
the piping.
Check the piping connections and secure fixing
of pump; if required, reduce distances
between the pipe clamps.Fix the pipelines
using anti-vibration material.
-
-
-
-
-
✘
Insufficient or excessive quantity of lubricant
or unsuitable lubricant
Top up, reduce or change lubricant.
✘ ✘
-
-
-
- Motor is running on two phases only.
Replace the defective fuse.
Check the electric cable connections.
-
✘
-
-
-
- Operating voltage is too low.
Increase voltage; check voltage drop in the
power cable.
-
-
-
-
✘
- Impeller is out of balance.
Clean the impeller.
Re-balance the impeller.
-
✘
-
-
✘
- Defective bearing(s)
Replace.
-
-
-
-
✘ ✘
Flow rate is too low.
Increase the minimum flow rate.
✘
-
-
-
✘ ✘
Magnetic coupling has dropped out of
synchronisation with motor.
Switch off the motor and re-start.
Check motor starting.
-
-
✘
-
-
- System pressure is too high.
Check system.
-
-
-
✘
-
- Defective shroud
Repair necessary.
-
-
-
-
✘
- Magnetic coupling out of balance (inner and
outer rotor)
Check balancing.
-
-
-
-
-
✘
Cooling circuit of magnetic coupling
interrupted
Repair necessary.
12)
The fault can also be remedied by changing the impeller diameter.
Summary of Contents for Magnochem-Bloc
Page 1: ...Mag drive Pump Magnochem Bloc Installation Operating Manual...
Page 93: ......
Page 94: ......