MDX [en-US]
49
11
Tooling
11.1
Torque Requirements
Torque requirements listed below and in previous sections are for lubricated bolting. All bolts must be lubricated to ease in pump
assembly and disassembly. Anti seize compound is preferred, but well oiled is also acceptable.
Special Torque Requirements
Fastener torque must be accurately measured to achieve the proper clamping force as defined either on the assembly
drawing or previous sections listed below. The use of a Hydraulic Torque Wrench is recommended as these tools can
be calibrated to produce the necessary accuracy.
For bearing housing hold down bolt torque refer to Section 8.4 "Bearing Assembly Mounting".
If the pump is equipped with an impeller release ring refer to 10.3 "Wet End Assembly" for torque requirements.
If the pump is equipped with a mechanical seal is used refer to the Mechanical Seal Manual for torque requirements.
Non-Critical Torque Requirements
No special torque requirements exist for the remaining nuts and bolts unless specifically called for on the assembly drawing.
Bolts and nuts for which torque is not specified should be tightened enough to ensure a firm mating between parts in accordance
with good maintenance practice. Where possible, the use of an air driven impact wrench is recommended for bolts over one
inch (25 mm) in diameter.
ENGLISH FASTENERS
Size
Anti-Sieze
Lubricated / Oiled
Pump Assembly
Fasteners
Mounting Equipment
to Sub Base
Pump Assembly
Fasteners
Mounting Equipment
to Sub Base
ft-lbs
N-m
ft-lbs
N-m
ft-lbs
N-m
ft-lbs
N-m
1/4"
3
5
5
6
5
6
7
9
3/8"
12
17
17
23
19
25
25
35
1/2"
30
40
40
55
45
60
60
85
5/8"
60
80
85
115
90
120
125
170
3/4"
105
145
150
200
160
215
220
300
7/8"
175
230
240
325
250
350
360
485
1"
260
350
360
490
385
520
540
730
1 1/8"
320
430
445
600
470
645
660
900
1 1/4"
450
610
620
850
670
910
940
1,275
1 3/8"
590
800
825
1,115
880
1,195
1,225
1,670
1 1/2"
780
1,060
1,090
1,480
1,170
1,585
1,635
2,220
1 3/4"
915
1,240
1,280
1,735
1,370
1,850
1,920
2,600
2"
1,375
1,864
1,925
2,610
2,060
2,795
2,885
3,910
2 1/4"
2,010
2,726
2,815
3,815
3,015
4,085
4,220
5,725
2 1/2"
2,750
3,729
3,850
5,220
4,125
5,590
5,775
7,825
METRIC FASTENERS
Size
Anti-Sieze
Lubricated / Oiled
Pump Assembly
Fasteners
Mounting Equipment
to Sub Base
Pump Assembly
Fasteners
Mounting Equipment
to Sub Base
ft-lbs
N-m
ft-lbs
N-m
ft-lbs
N-m
ft-lbs
N-m
M8
8
11
10
14
10
15
16
20
M10
15
21
20
28
20
30
30
40
M12
25
35
35
50
40
50
55
75
M16
65
90
90
125
100
130
135
180
M20
130
180
180
250
195
265
270
370
M22
175
250
240
335
260
360
370
500
M24
225
315
305
425
335
450
470
640
M27
325
455
440
615
490
660
680
925
M30
450
625
605
850
670
910
940
1,270
M36
780
1,090
1,060
1,480
1,170
1,600
1,640
2,220
M38
920
1,285
1,250
1,740
1,375
1,865
1,930
2,615
M39
995
1,390
1,350
1,885
1,490
2,020
2,090
2,830
M42
1,245
1,740
1,685
2,360
1,865
2,530
2,610
3,540
M48
1,860
2,610
2,525
3,540
2,795
3,790
3,910
5,300
M64
4,445
6,220
6,025
8,440
6,670
9,040
9,335
12,650
Values based on Grade 5 fasteners
Torque Values taken at
50% Proof Strength for Pump Assembly Fasteners
70% Proof Strength for Mounting Equipment to Sub Base
K-Factors = 0.120 for Anti Sieze
0.180 for Lubricated / Oiled
Summary of Contents for GIW MDX