MDX [en-US]
9
3
Transport and Storage
3.1
Transport & Handling Safety
WARNING
Proper rigging, lifting and safety practices must be observed at all times.
If the pump / unit slips out of the suspension arrangement, it may cause personal injury and damage
to property.
Follow proper lifting practice and safety rules at all times, including:
Verification of the lift weight and load rating of the lift equipment.
Suitability and stability of the attachment points.
Be aware of the location of the center of gravity, which is usually NOT located at the physical center of the unit. In
general, the following guidelines will apply, although common sense and testing of the lift before movement should be
used to verify:
Bare shaft pump (without motor): Near the shaft seal area.
Pump with overhead mounted motor: Between the pump and motor, slightly behind (towards the drive end) of
the shaft seal.
Vertical cantilever pump: between the pump and bearing assembly, but closer to the bearing assembly.
Space the lifting points evenly about the center of gravity and as far apart as practical. This will result in the most stable
lift. Note that certain lift points on the pedestal or bearing housing may be intended for use in handling the pedestal or
bearing house alone and are not necessarily optimum balance points for the entire pump unit.
See Section 3.3 or any addendums for suggested lifting methods. Actual safe lifting method will vary with pump
configuration and type of lifting equipment.
Ensure secure attachments and test the lifting method for stability before moving pump.
For horizontal pumps, ensure that the unit remains in the horizontal position during lifting and cannot slip out of the
suspension arrangement.
Ensure that the pump is firmly strapped down during shipment. Pump should be protected from direct contact with the
elements. Motors and gear reducers may require Immediate cover (consult manufacturer). After arrival on site, consult
GIW Pump Storage recommendations for further storage instructions.
In corrosive environments be sure to remove all lifting devices from the pump and store in a non-corrosive environment
until needed.
DO NOT: Use eyebolt or shackle locations on the bearing assembly, motor or pump plates. These are intended for
lifting those items alone and must not be used when lifting the entire pump.
DO NOT: Place excessive side loads on cast lifting eyes. The side loading angle on any lifting eye should not exceed
30 degrees.
3.2
Storage Requirements
3.2.1
Storage of New Pumps - Pumps under Warranty
Consult your sales contract documents and/or your GIW / KSB representative for detailed instructions. Note that failure to follow
proper storage procedures will void your warranty.
3.2.2
Pump Storage
CAUTION
In freezing environments, water must be prevented from collecting in the pump casing.
Pumps with elastomer linings should be stored in a cool dark location free from electrical equipment
such as motors, or any other ozone generating devices. Exposure to direct sunlight or temperatures in
excess of 50°C (120°F) must be avoided.
If the pump is fitted with a mechanical seal, motor, sheave, bushing, coupling, gear reducer, or other
auxilarily equipment be sure to consult the manufacturer’s maintenance manual for any additional
storage instructions.
Auxiliary systems should be regularly tested according to manufacturer’s recommendations.
Summary of Contents for GIW MDX