Installation at Site
5.1
Safety Regulations
WARNING
Electrical equipment operated in hazardous locations must comply with the applicable explosion protection
regulations. This is indicated on the motor rating plate. If the equipment is installed in hazardous locations, the
applicable local explosion protection regulations and the regulations of the test certificate supplied with the
equipment and issued by the responsible approval authorities must be observed and complied with. The test
certificate must be kept close to the location of operation for easy access.
5.2
Foundation
WARNING
Appropriate personal protective equipment should be worn when handling concrete and grouting materials.
All structural work required must have been prepared in accordance with the dimensions stated in the dimension table /
installation plan.
The concrete foundation shall have sufficient strength for the pump and be completely cured before installation. The mounting
surface must be flat and level. Anchor bolts must be located according to the installation plan. This can be done when the
concrete is poured, or by drilling holes in existing foundations and grouting the bolts in place.
5.3
Installing the Baseplate and Pump
WARNING
Do not install the baseplate and pump on unpaved or unsupported foundations. Injury can result from vibration
or shifting equipment.
After placing the baseplate on the foundation, it must be leveled by shimming. Shims should be fitted between the baseplate
and the foundation itself; they should always be inserted to the left and right of the foundation bolts and in close proximity to
these bolts. For a bolt-to-bolt clearance of more than 800mm (30 inch), additional shims should be inserted halfway between
the adjoining holes. All shims must lie perfectly flush.
Insert the foundation bolts and set them into the foundation using concrete. When the mortar has set, tighten the foundation
bolts evenly and firmly and grout the baseplate using low shrinkage grout.
1
Shim
2
Foundation Bolts
3
≤ 800 mm
5.3.1
Aligning the Pump / Drive Train for Horizontal Pump Application
WARNING
Use of the mounting bolts to close gaps between motor feet and the mounting plate (in place of
shimming) is not recommended and may result in twisting of the motor frame, "soft foot" mounting and
excessive vibration.
Care must be taken when removing drive components to avoid personal injury or damage to the
equipment. Avoid contact with hot surfaces such as couplings, which may heat up during normal
operation and cause injury.
3
1
1
1
2