4 Valve Description
67 of 100
Part
No.
Description
Material
A 216 WCB A 217 WC6 A 217 WC9 A 217 C5
A 217 C12
A 352 LCB
A 352 LCC
A 351 CF8
A 351 CF8M
920.2
Nut
A 194 2H
A 194 Gr. 7
A 194 Gr. 7
A 194 Gr. 7
A 194 Gr. 7
A 194 Gr. 7
A 194 Gr. 7
A 194 Gr. 8
A 194 Gr. 8
920.1
Nut
A 194 2H
A 194 Gr. 7
A 194 Gr. 7
A 194 Gr. 7
A 194 Gr. 7
A 194 Gr. 7
A 194 Gr. 7
A 194 Gr. 8
A 194 Gr. 8
902
Stud
A 193 B7
A 193 B16
A 193 B16
A 193 B16
A 193 B16
A 320 L7
A 320 L7
A 193 B8
A 193 B8
916
Plug
Carbon steel Carbon steel Carbon steel Carbon steel Carbon steel Carbon steel Carbon steel Stainless
steel
Stainless
steel
Table 76: Trim materials
Part No.
Description
Trim 1
Trim 2
Trim 5
Trim 8
Trim 10
13% chrome steel (Cr) /
13% chrome steel (Cr)
304 / 304
Stellite / Stellite
Stellite / 13% chrome
steel (Cr)
316 / 316
746
Valve disc
13% chrome steel (Cr)
304 stainless steel
Stellite
13% chrome steel (Cr) 316 stainless steel
515
Seat ring
13% chrome steel (Cr)
304 stainless steel
Stellite
Stellite
316 stainless steel
210
Hinge pin
13% chrome steel (Cr)
304 stainless steel
13% chrome steel (Cr) 13% chrome steel (Cr) 316 stainless steel
4.7.1.6 Function
The main components of the swing check valves are the body (100), the cover (160)
and the valve disc (746).
Seat/disc interface
The hard-faced seat ring (515) is welded into the body (100). The seating surface of
the valve disc (746) is hard-faced. The valve disc (746) is mounted on the hanger arm
(570) by means of a nut (920.3) and pin. The hanger arm (570) pivots on a hinge pin
(210) mounted inside the body (100).
Bonnet/cover seal
The body (100) and the cover (160) are connected by studs (902.1) and nuts (920.1).
The joint is sealed by means of a joint ring (411).
4.7.2 ECOLINE SCF 150-600
4.7.2.1 Operating data
Table 77: Operating properties
Characteristic
Value
Nominal pressure
Class 150 - 600
Nominal size
NPS ½'' - 2''
Max. permissible pressure
104 bar / 1480 PSI
Min. permissible temperature
0 °C / 32 °F
Max. permissible temperature
816 °C / 1500 °F
Temperatures < 0 °C on request
Selection as per pressure/temperature ratings
(
ð
Section 4.7.2.4, Page 69)
4.7.2.2 Fluids handled
▪
Steam
▪
Fluids containing gas
▪
Gas
▪
High-temperature hot water
▪
Volatile fluids
▪
Feed water
Summary of Contents for ECOLINE FYC
Page 4: ...Contents 4 of 100 9 5 EU Declaration of Conformity for ECOLINE GLB 150 600 95 Index 96...
Page 98: ......