3 Transport/Temporary Storage/Disposal
12 of 100
3.4 Return to supplier
1.
Drain the valve as described in the manual.
2.
Always flush and clean the valve, particularly if it has been used for handling
noxious, explosive, hot or other hazardous fluids.
3.
If the fluids handled by the system leave residues which might lead to corrosion
damage when coming into contact with atmospheric humidity, or which might
ignite when coming into contact with oxygen, the valve must also be neutralised
and blown through with anhydrous inert gas for drying purposes.
4.
When returning valves used for handling Fluids in Group 1 always complete and
enclose a certificate of decontamination.
Always indicate any safety and decontamination measures taken.
NOTE
If required, a blank certificate of decontamination can be downloaded from the
KSB web site at:
www.ksb.com/certificate_of_decontamination
3.5 Disposal
WARNING
Fluids, consumables and supplies which are hot and/or pose a health hazard
Hazard to persons and the environment!
▷
Collect and properly dispose of flushing fluid and any residues of the fluid
handled.
▷
Wear safety clothing and a protective mask, if required.
▷
Observe all legal regulations on the disposal of fluids posing a health hazard.
1.
Dismantle the valve.
Collect greases and other lubricants during dismantling.
2.
Separate and sort the valve materials, e.g. by:
- Metals
- Plastics
- Electronic waste
- Greases and other lubricants
3.
Dispose of materials in accordance with current regulations or in another
controlled manner.